Installing a redundant power supply
Desktop or shelf mounting
1. Attach the four adhesive feet to the bottom of the first RPS device.
FIGURE 21
2. Set the device on a flat surface near an AC power source, making sure there are at least two

Connecting devices to the redundant power supply

The RPS2-EIF unit can be used with all FastIron LS and FastIron LS-STK devices.
Follow the steps below to connect devices to the redundant power supply.
1. Connect one end of the AC cable to the AC receptacle on the supported device, and the other
FIGURE 22
2. Connect one end of a DC cable to the redundant power receptacle on the supported device
3. Repeat steps 1 and 2 for connecting up to four supported devices to the RPS device.
4. Connect one end of the AC cable to the AC receptacle on the RPS device, and the other end to
22
DRAFT: BROCADE CONFIDENTIAL
Attaching the adhesive feet
inches of space on all sides for proper air flow.
end to a grounded power outlet.
Power receptacle
RPS 1
and the other end to an available receptacle on the RPS device.
a grounded power outlet.
Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide
100-240V, 50-60Hz 10A