Ac Power Supply; Power Cables; Redundant Power Supply Specifications - Brocade Communications Systems LS-STK Installation Manual

Ethernet modem
Table of Contents

Advertisement

7

Redundant power supply specifications

TABLE 23
Cable specifications (Continued)
Cable type
10GBase-XFP
MMF
MMF
10GBase-ZR
SMF
10GBase-ZRD
SMF

AC power supply

The FastIron LS and LS-STK devicees include an integrated AC power supply with a standard IEC
type (IEC320) input connector, that operates at 85 VAC to 254 VAC input, universal or wide input.
AC power specifications
TABLE 24
Property
Input voltage range
Input current
Inrush current
Power consumption
(without modules)
Power consumption
(with all modules)
Max output power

Power cables

All FastIron devices ship with US-compatible power cables unless otherwise specified at the time of
order. United Kingdom- and European-compatible power cables are also available.
Redundant power supply specifications
The optional Redundant Power Supply (RPS2-EIF) can supply backup power to four attached
devicees (FLS627, FLS648, FLS624-STK and FLS648-STK) in the event of an AC power loss or the
failure of an internal power supply.
For more information, see
66
DRAFT: BROCADE CONFIDENTIAL
Connector type
LC connector for XFP module
LC connector for XFP module
LC connector for XFP module
AC power specifications
FLS624
100 - 240 VAC
< 3 Amps
< 8.5 Amps peak maximum
65 W
105 W
156 W
"Installing a redundant power supply"
Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide
Core diameter
Modal bandwidth
(microns)
(MHz km) or
Wavelength (nm)
62.5
1310 nm
50
160 or 200 and
400 or 500
9
1550 nm
9
1530.33 –
1561.42 nm
FLS648
100 - 240 VAC
< 3 Amps
< 12 Amps peak maximum
85 W
120 W
156 W
on page 17.
Range (meters)
200 m
200 m
up to 80000
(80 km)
up to 80000
(80 km)
53-1002187-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fastiron lsFastiron ls-stk

Table of Contents