Brocade Communications Systems LS-STK Installation Manual page 60

Ethernet modem
Table of Contents

Advertisement

5
Managing FastIron LS temperature settings
To display the temperature of a device, enter the show chassis command at any level of the CLI:
FLS648 Switch> show chassis
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok, speed (auto): [[1]]<->2<->3
Fan 2 ok, speed (auto): [[1]]<->2<->3
Fan 3 ok, speed (auto): [[1]]<->2<->3
Fan controlled temperature: 37.0 deg-C
Fan speed deviceing temperature thresholds:
Sensor B Temperature Readings:
Sensor A Temperature Readings:
Boot Prom MAC: 001b.ed5d.9f00
Management MAC: 001b.ed5d.9f00
The following output is from the show chassis command on an IronStack Active Controller.
Temperature settings for an IronStack are displayed globally.
FLS648P device# show chassis
The stack unit 1 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Intake Side Temperature Readings:
Boot Prom MAC: 0012.f2de.9440
Management MAC: 0000.0000.0011
The stack unit 2 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
--More--, next page: Space, next line: Return key, quit: Control-c
50
DRAFT: BROCADE CONFIDENTIAL
Speed 1: NM<----->50
Speed 2:
Speed 3:
Current temperature : 37.0 deg-C
Warning level.......: 55.0 deg-C
Shutdown level......: 90.0 deg-C
Current temperature : 33.5 deg-C
Current temperature : 35.5 deg-C
Warning level.......: 80.0 deg-C
Shutdown level......: 90.0 deg-C
Current temperature : 33.5 deg-C
Brocade FastIron LS and FastIron LS-STK Hardware Installation Guide
deg-C
40<----->55
deg-C
50<-----> 90 deg-C (shutdown)
53-1002187-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fastiron lsFastiron ls-stk

Table of Contents