Panic Keys
There are three lettered keys or (on some keypads, panic key pairs) that, if
Relay~owerline Carrier
Devices
(if used)
4285
Module
(if used)
Exit Alarm
Displays
(if programmed)
programmed, can be used to manually initiate alarms and send a report' to
the central station.
Each can be individually programmed for 24-hour Silent, Audible, Personal or
~
Fire Emergency responses.
The panic function is activated when the ap-
propriate lettered key is pressed for at least 2 seconds, or the appropriate key
pair are pressed at the same time.
The panic functions are identified by the system as follows:
Keys
Displayed as Zone
Notes:
[A,
or [11& [*I
95
Keys
[A],
[B], [C]
are
not
on
all
[B],m [*Ik [#l
99
keypads.
Key [D], if present, is not active
[C], or [3]& [#]
96
here.
Important:
For the Silent Panic functions to be of practical value, the
system must be connected to a central station.
If relay outputs (via a 4204, or 4229), or Powerline Carrier devices are used,
two keypad entries available to the user are included. They can manually
activate or deactivate the device(s) for starting or stopping some action, such
as turning lights on or off, etc.
These keypad entries are:
Security Code + [#] +
[7]
+
Device # activates (starts) that device.
Security Code + [#] + [8] + Device # de-activates (stops) that device.
Refer to the separate instructions supplied with the 4285 module for
information concerning its operating procedures.
Note: The 4285 module cannot be used to add user codes in this system.
User codes must be added by using a wired keypad.
*
A display
of "CANCELED
ALARM" or "CA" and a zone indication
will appear if an exit or interior zone contained a fault during closing at
the time the exit delay ended (e.g., exit door left open), but the system was
disarmed during the entry delay time. The alarm sounder and keypad
sound continuously, but stop when the system is disarmed. No message
will be transmitted to the central station.
" A display of '!EXIT ALARM" or "EAt' and a zone indication will
appearif an exit or interiorzone containeda fault duringclosingat the
time the exit delay ended, but the system was NOT disarmed during the
entry delay time. The alarm sounder and keypad sound continuously until
the system is disarmed (or timeout occurs). An "exit alarm" message is
sent to the central station.
The 'EXIT ALARM" display, etc. will also result if an alarm from an
exit or interior zone occurs within two minutes after the end of an exit
delay.
In any of the above cases, use a second OFF sequence (code plus OFF key) to
clear the display.