ADEMCO Vista-20HW Installation Instructions Manual page 68

2-partitioned security system
Table of Contents

Advertisement

Press
*9O EVENT LOGGING
•1
O= None; 1 = Alarm/Alarm Restore; 2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore; 8 = Open/Close. Default is "3".
Exampku To select "Alarm/Alarm Restore", and "Open/Close", enter 9
~
(1+ 8); to select all, enter #15.
Note: System messages are logged when non-zero selections are made.
See Fields *89 and *9O in Section 17. DATA FIELD DESCRIPTIONS
for a more detailed description of Event Logging.
Press W12.PHONE LINE MONITOR ENABLE.
•1
O= Not used (default)
1 = Local keypad display only when phone line is faulted.
2 = Local keypad display plus keypad trouble sound when line is faulted.
Each partition turns off its own trouble sound. No automatic timeout.
I
3 = Same as "2" above plus Device No. 2 STARTS. If either partition is
NOTE:
Option 3 may be used
armed, external sounder activates. External sounder will be turned off
by normal bell timeout, or by security code plus OFF from either
even if a relay unit or
Powerline carrier device
partition
(it
does not have to be the one that was armed).
Device number 2 must either be programmed to be STOPPED in field
is not connected to the
*8O or STOPPED
by
entry
of sectity
code + # + 8 + 2. Partition in
control.
*8O should be set to "O"for STOP.
Press *93 NUMBER OF REPORTS IN ARMED PERIOD
"O" limits reports to a total of 10 per code; "1" allows an unlimited
number of al~
plus alarm restore-reports. "Defaultis O.
Enter "1" for UL installations.
Press *94 DOWNLOAD PHONE NUMBER
I
11111111111
Enter up to 12 digits;
O-9, # +11 for "w, # + 12 for "#", # + 13 for a pause. Do not fill unused
spaces. End field by entering "*". To clear entries, press *94*.
Press *95 RING DETECTION COUNT FOR DOWNLOADING
n
Refer to the chart below and program this field accordingly.
*96
INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. No.
FOR DOWNLOADING
(No data entry required)
This completes
the commwzicafion
programming.
Exit the programming modeby keying*9.
Referto Section 19. TESTING THE SYSTEM
to
check system operation.
Voice
Answering
Module
Machine
Downloading Field *95 ProL
"L?
Yes
No
No
Set for value otherthan "O"(1-15).
This will enablethe controlpanel to
answerthe phone call. Otherwise,it
won't be possibleto accessthe Module.
Yes
Yes
No
Set for a value higher than the number
of rings for which the answering
machineis set. Example: if machineis
set for 4 rings,use value 5 or higher.
This is recommendedso that the Voice
Modulecan stillbe accessedif the
answering machineis turned off and
does not answerthe phone call.
Yes
No
Yes
Set for value otherthan "O"(1-15).
Yes
Yes
Yes
"15" to bypass answeringmachine.
No
No
No
Enter "O"
No
Yes
No
Enter "O"
No
No
Yes
Enter 1–15
No
Yes
Yes
Enter 15