This section lists the wired keypads that may be used and provides
instructions for wiring and mounting the keypads.
A preliminary check-out procedure is also provided to ensure that the
-
connected keypads are fi.mctioning properly in the system.
Keypads That May Be Used
Q Fixed-Word Display: 4137AD, 4127,6127,6128,6137
" Alpha Display 5137AD, 6138,6139
" Up to 4 keypads in each partition (total of 8 in the system), independent of
auxiliary power considerations (you may need to use an auxiliary power
supply if the 600mA auxiliary output is exceeded)
WIMg To The Keypads
1.
Determine wire gauge by referring to the wiring length/gauge
chart
below. Wire lengths/gauge for Partition 2 keypads should be determined
separately from those keypads connected to Partition 1.
2.
Run field wiring from the control to the keypads (using standard 4-
conductor twisted wire cable using the wire gauge determined in step 1).
I
Wiring Run Chart For Devices* Drawing Aux Power
From 'l'he Control (12V+ & 12V-)
I
TOTAL CURRENT
DRAWN BY ALL DRVICES CONNECTED
TO A S~GLE
WIRE RUN
Wire Size
50 mA or less
I
100 InA
I
300 mA
I 500 IIA
I
600 rnA
#22
500 ft (152m)
250ft (76m)
80 R (24m)
50 f%(15m)
42 ft (13m)
#20
750 ft (228.6m)
380ft (l16m)
130it (39.6m)
80 f%(24m)
67 ft (20.4m)
#18
1300R (396m)
650ft (198m) 220 ft (67m)
130ft (39.6m) 115ft (35m)
#16
1500ft (457m)
1000ft (305m) 330ft (100.5m)
200 f%(70m)
170ft (52m)
* IncludesKeypads,Zone Expander/Relay Units,or 4285Module.