Programming Wired Expansion Zones - ADEMCO Vista-20HW Installation Instructions Manual

2-partitioned security system
Table of Contents

Advertisement

Programming
Wined Expansion Zones
1. With at least one 2-line Alpha keypad (5137AD or 6139) connected to the
Partition 1 keypad terminals on the control, power up the system
temporarily. If you had previously connected the AC transformer to the
control panel, you need only plug in the transformer (to 120VAC outlet) to
power up the system.
2.
Enter the programming
mode by keying the following on the Alpha
keypad:
Installer code (41 12) + 8 + O + O.
3.
Press *56.
Note that this k an interactive
programming mode. It is used
to program zone numbers, zone types, partition numbers, and alsrm
report codes for all zones that are going to be used.
-L ZoneNumber
Ezziil
II 10
Partition
II
Enter the first zone number that you wish to
program (or [01[01 to exit zone programming).
Normally, you will be starting with zone 10, so
enter "1O". Press [*] to continue.
A summary display will appear, showing the
present status of that zone's programming.
Zn = zone numbe~
ZT = zone @pw
P = partition to which zone is assigned;
RC = report code for that zone;
In= input type of zone (AW for Aux Wired).
L = Loop (not used for wired expansion zones)
Values
in the summary
display
are the
currently programmed values.
To start programming zone 10, press [*]. A
prompt for Zone Type will appear.
Each zone must be assigned a zone type, which
defines the way in which the system responds to
faults in that zone. A detailed explanation of
each zone type is provided in "Response ~pe
Definitions" in Section 16. ZONE RESPONSE
TYPE DEFINITIONS.
Enter the desired zone type,as listed below.
00= ZoneNot Used
07= 24 Hr Audible
01= Entry/Exit#1
08=24 HrAux
02= Entrv/Exit#2
09= Fire
03= PeAeter
10= Interiorwillelay
04= InteriorFollower
23= No Alarm
05= TroubleDay/AlarmNight
Response
06= 24 Hr Silent
24= SilentBurglary
When the display shows the zone type you want,
press [*] to continue.
Enter the partition to which a zone is to be
assigned.
Enter "l" or "2".
The default is
partition 1.
Press [*] to continue.
-26-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-20hw

Table of Contents