Programming For The Remote Keyswitch - ADEMCO Vista-20HW Installation Instructions Manual

2-partitioned security system
Table of Contents

Advertisement

Programming For The Remote Keyswitch
1. With at least one 2-line Alpha keypad (5137AD or 6139) connected to the
Partition 1 terminals, power up the system. If you had previously
connected the AC transformer to the control panel, you need only plug in
the transformer (to 120VAC outlet) to power up the system.
2.
Enter the programming mode by entering:
Installer code (41 12) + 8 + O + Okeys.
Note: If keyswitch is enabled, in menu mode *56 the Zone Type (ZT) for
zone 7 will show "77", and will not be accessible for programming.
3. Press *56.
Note that this is an interactive programming mode. You will use it to
program zone 7 for partition number, alarm report codes, and to program
response time (zone type will automatically show as '77").
ml
ZoneNumber~
Typicalsummarydisplay
II
ZnZTPRCln
RT
0777
1
00
HW:
1
II
J Zone Number
II
07 Zone
Type
77
II
ZoneType
'1'
II
07
Partition
1
II
Upon entering *56 mode, this prompt will be
displayed.
Enter zone number "07" (if not already
present).
Following this entry, press *to continue.
A summary display will appear, showing the
present status of zone 7's programming.
Zn = zone numbeq
ZT = zone type;
P = partition to which zone is assigned
RC = report code for that zone;
In= input type of zone;
RT = response time for that zone.
Values displayed are the factory defaults for
zone 7 or, if this is not a new installation,
they are the currently programmed values.
To program zone 7, press [*I.
Zone type will be automatically displayed as
"77", and no entry is required.
Press [*] to continue.
The partition
to which the keyswitch
is
assigned is entered here. Enter "l" or "2". Note
that the
Keyswitch arming may only be used in
one partition. (Default = [1].
Press [*] to continue.
The report code consists of 2 hexadecimal
digits, each in turn consisting of 2 numerical
digits. For example, for a report code of "3C",
enter [01[31for "3" and [11[21for "C".
If necessary, refer to Section 15. SYSTEM
COMMUNICATION
for complete informa-
tion on report codes.
Enter the desired numbers and then press
[*] to continue.
-50-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-20hw

Table of Contents