Check-Out Procedure For Wired Expansion Zones
After you have completed installation of all devices, all expansion zones in
each partition of the security system should be checked as follows:
1.
2.
3.
4.
5.
Make certain that all devices and sensors connected to the wired
~
expansion zones are not in a faulted state. Doors and windows with
contacts should be closed, PIRs should be covered (use a cloth to mask
them temporarily if necessary).
With all zones intact (including hard-wired zones), the Alpha keypad
connected to the system should display:
~~
If the following is displayed,
~,
press the [*] key to display the faulted zone(s).
Restore any faulted
zone(s) as necessary (also make sure that you have comected a 1000 ohm
EOL resistor across the terminals of unused expansion zones on the 4219
or 4229 module).
When the READY TO ARM message is displayed, you can proceed to the
next step.
Fault and restore every contact or sensor in each expansion
zone
individually to ensure that it is being monitored by the system. Each time
a zone is faulted, the keypad should display the number of the faulted zone
(as programmed by you just previously in *56 mode). When each zone is
restored, the READY TO ARM message should appear again.
If some wired expansion zones have been assigned to partition 1 and
w
others to partition
2, you will need to observe the keypad in the
appropriate partition as each zone in that partition is faulted and restored.
When you get the proper displays on the keypad(s), the wired expansion
zones in the system are fimctioning properly.
Unplug the AC transformer.
.