SYSTEM STATUS
*59
REPORT CODES
(*59-W3)
*60
*61
*62
*63
*64
*65
*66
*67
*@
EXIT ERROR REPORT CODE (Seebox previously)
•1
If the system is armedand an Entry/Exitor Interiorzoneis still open
after the exit delay time has expired, an alarm will sound at the
keypadand external sounder(keypadalso displays "Exit Alarm"). If
the system is disarmed before the end of the entry delay that
immediatelyfollows,the alarm soundingwill stop and no message
wiIl be sent to the central station. The keypad will display CA
(fied-word keypads)or CANCELEDALARM (Alphakeypads).
If the system is not disarmed before the end of the entry delay
mentionedabove,and an Entry/Exitor Interiorzone is still open, an
'exit alarm" message will be sent to the central station if an
Exit Error Report code is selected in this field. The keypadwill
display EA (fixed-wordkeypads)or EXIT ALARM (Alpha keypads),
and the zdarmsoundingwill continueuntil the system is disarmed(or
timeoutoccurs).
An "ExitAlarm" condition will alsoresultif a fault occursin an exit or
interiorzone within2 minutesfollowing the end of the exit delay, and
an "exitalarm"messagewillbe sentto the centralstation.
If ContactID formathas been programmed,the message will contain
the zonenumbersnd errorcode374 (Troubl*Exit Error)to definethe
alarm as an Exit Error(ratherthan E/E or Interior).If 4+2 format is
used, the digitenteredin this fieldwill be sent followedby the second
digitof the programmed alarmcodeforthat zone. If 3+1 or 4+1 format
is used, only the digit enteredin this field will be sent. This message
will go to the PrimaryPhone No. Under any of these conditions,no
Restoremessagewillbe sent.
If "O"is enteredin this field,no specialmessage will be sent, only the
regularalarmand alarmrestorecodefor the zone.
TROUBLE REPORT CODE (Seebox previously)
m
BYPASS REPORT CODE (Seeboxpreviously)
m
AC LOSS REPORT CODE
m
See box on previouspage. Reportswith Partition 1 SubscriberNo.
Timing of this reportis random with up to a 4-hour delay. If AC
restoresbeforethe reportgoesout,thereis no AC restorereport.
LOW BAT REPORT CODE
m
See box. ReportswithPartition1 Subscriber No.
TEST REPORT CODE
See box. Periodic Reports with Partition
OPEN REPORT CODE
See box on previous page. 2nd digit =
reporting is selected.
ARM AWAY/STAY REPORT CODE
m
1 Subscriber No.
•1
User #, if expanded or 4+2
r-i---l
This option allows for independent programming of AWAY and~Y
reports for each partition. 2nd digit of report is User No. if expanded
or 4+2 reporting is selected.
RF XMTR LOW BAT REPORT CODE.
(NOT
USED)
CANCEL REPORT CODE
(Seebox on previouspage.)