Rek@Powerlime Carrier Device Basks
Relays and Powerline Carrier
devices (ex. X-10 brand
devices) are
programmable switches that can be used to perform many difRerent functions.
They can be used to turn lights on and off, control sounders, or for status
indications. In this system, each devicemust be programmed as to how to
act (ACTION), when to activate (START), and when to deactivate (STOP).
Each of these is describedbelow, and in the progr axnmingprocedure for *8O
and *81 interactivemodesthat me provided at the end of this section.
The control supports a total of 8 output devices in the following
con.@urations:
One 4204
relay module (4 relays) and 4 PowerlineCarrier devices.
One 4229 zonehelay module (2 relays) and
6
Powerline Carrier devices.
c Up to 8 Powerline Carrier devices(8 minus the number of output relays
used).
The 4204
and
4229
modules provide Form C (normally open and
normally
closed) contacts. Powerline Carrier devices are controlled by signals sent
through the electrical wiring at the premises via a 4300 transformer.
Therefore, if using Powerline Carrier Devices, a 4300 transformer
must
be
used in placeof the regular systemtransformer.
In *8O and *81
interactive modes, a series of keypad prompts wdl request
entries for progr amming of the Relay outputs and/or Powerline Carrier
devicesused in the system. Refer also to "OUTPUT RELAYS/POWERLINE
CARRIER
DEVICES
WORKSHEET
FOR *8O AND *81 INTERACTIVE
MODES" in the blank programming g form.
4204
and 4229
Reky Modules
4204/4229
-p
The 4204
or
4229
unit can be mounted either remotelyor in the control panel.
The following stepsshould be taken to properly setup the 4204 or 4229:
1.
Connect
the 4204/4229 to the control's Partition 1 remote keypad
terminals (4-7),
using the connector supplied with the 4204 and 4229.
Use standard 4conductor twisted cablefor long wiring runs.
2. Set the 4204/4229's D~
switch for a device address of 'l" (switch 2
"OFF" md switches3, 4, 5 "ON"). Switch 1 determines tie tit's
cover
tamper response("ON = disabled,"OFF"= enabled).
3. Connect the desired field wiring
to the unit's relay contactterminals.
Supervision
c 4204
and
4229
modules are supervised against removal.
CHECK
and
zone 09 will be displayed if a module is disconnectedfkom the control's
txxminals
(4,5,6, & 7).