Turn On The System; Configuration Settings; Settings 1 - 19 - Wine Guardian Through-the-Wall Installation, Operation And Maintenance Manual

Through-the-wall wine cellar cooling systems
Hide thumbs Also See for Through-the-Wall:
Table of Contents

Advertisement

Turn on the System

Plug in the system. Touch the on/off bottom on front panel. The display lights up to indicate
power to the system. The system may not come on right away due to the timer built into the
circuiting toprevent short-cycling. There is a 5-minute compressor/condenser fan time delay on
initial start-up.
On/Off - The On/Off button will be used to turn the system on or off. When set to the off
mode the control will not allow any of the outputs to energize effectively locking the system
out. It will not allow any outputs to energize until the system is turn on with the on/off button. It
should be noted that high voltage will still be present at the main control board when the
system is set to off even though the control will not allow it to switch to the outputs.
Up Arrow - The Up arrow will allow the user to increase settings.
Do
wn Arrow - The Down arrow will allow the user to decrease settings.
Mode - The mode button will be used to select between heat and cool mode, as well as
entering the configuration settings. Holding the Mode button for 5 seconds will enter configura-
tion mode. Once in configuration mode the user can adjust settings by pressing the Up or
Down arrows. Pressing the Mode button once will advance to the next configuration setting.
Holding the Mode button for 5 seconds while in configuration mode will store all changes and
exit configuration mode.
.

Configuration Settings

Setting 1
Setting 1 will allow the user to select the Fahrenheit or Celsius temperature scale. It will toggle between
F and C when the Up or Down arrows are pressed. The default is F.