Maintenance Schedule; Monthly; Yearly - Wine Guardian Through-the-Wall Installation, Operation And Maintenance Manual

Through-the-wall wine cellar cooling systems
Hide thumbs Also See for Through-the-Wall:
Table of Contents

Advertisement

Maintenance Schedule

Monthly

(or quarterly depending on experience with individual cellar)
√ Check for noise or vibration.
√ Check for short-cycling of the system - a turning on and off of the compressor unit
more than eight (8) times/hour.

Yearly

(in addition to monthly)
√ Check evaporator and condenser coils for dirt – use a vacuum with a brush attachment
to clean the coils.
√ Clean condensate pan under the evaporator coil by flushing. Be careful to keep the drain
pans clear of any and all debris.
√ Inspect cabinet for corrosion or rusting – clean and paint.
√ Inspect for dirt buildup on or inside the unit. Clean system by vacuuming or wiping it
down.
√ Check for loose insulation, fasteners, gaskets or connections.
√ Check the wiring connections and integrity of cords.
√ Examine condenser duct (if option is used) for any cracks or breach.
29