Wine Guardian Controls

Wine Guardian's digital electronic control series offers a versatile solution for controlling and monitoring
your wine cellar temperature and humidity. This series consists of four controls; a main control board; a local
user interface; a remote user interface; and a remote temperature and humidity sensor. The system only
requires the use of the main control board and one of the user interfaces (local or remote) to function.
However, users have the following options to customize the control capabilities for their application: (See
page 6 for description of control boards and optional sensors).
The Wine Guardian's digital electronic controls are designed to control the operation of the compressor,
condenser fan, evaporator fan, and humidifier. There also is pressure switch monitoring with a dry contact
alarm output that will energize in the event of a pressure switch fault or a high/low temperature or humidity
alarm. The local and remote user interface controls employ user-friendly, menu-driven programming features
that can easily be accessed by holding the mode button on the control for 5 seconds. Once in the program
menu, the user can scroll through the settings by pressing the mode button and can adjust each setting by
using the up and down arrows. The programming mode allows the user to customize features such as °F
or °C temperature scale, high/low temperature and humidity alarm set points, an adjustable 0-10 minute
compressor anti-short cycle delay, sensor averaging options, enable or disable the defrost feature, an
optional keypad lockout code, differential and dead band adjustments, room temperature calibration, enable
or disable the humidifier, and automatic or continuous fan option. To exit the programming mode the user
may either hold the mode button for 5 seconds or the control will automatically store the settings and exit the
programming mode after 10 seconds of inactivity. Each user interface control will also employs and ON/
OFF button that turns the system on or off respectively.