Humidity Too High When System Is Running But Not Cooling; Humidity Too High When System Is Not Running; Humidity Too High When System Is Running And Cooling; System Is Leaking Water - Wine Guardian Through-the-Wall Installation, Operation And Maintenance Manual

Through-the-wall wine cellar cooling systems
Hide thumbs Also See for Through-the-Wall:
Table of Contents

Advertisement

Humidity Too High When System is Not Running

Possible Cause
System needs to run to dehumidify

Humidity Too High When System is Running and Cooling

Possible Cause
Too much moisture in cellar
Other Miscellaneous Problems

System is leaking water

Possible Cause
Need external drain line
Trap plugged
Condensate pan plugged
System not level
System is Running Properly, but the Sound of System is
Objectionable
Possible Cause
Noise is from airflow
Solution
Lower room temperature setpoint. Seal open-
ings around doors (gasket and sweep)
Solution
Poor vapor barrier installation
Humidifier malfunction refer to the
humidifier instructions.
Add dehumidifier to surrounding space
Solution
Connect external drain line
Clean trap
Remove blockage and clean
Level with shims
Solution
Duct airflow from condenser to outdoors.