Starting-up and Operating the Wine Guardian PRO Split
System
Now that the installation is complete, check to make sure all ductwork and electrical connections
are secure.
Replace all panels that were removed during installation. Check that all of the openings in the unit
are covered with a blank panel, a ductwork connection or a grille.
COVER ALL OPENINGS OF THE UNIT TO PREVENT A HAND OR FINGER FROM ACCESS

Turn on the Unit

Plug in the unit. Turn on the rocker switch on the side of the unit. The rocker switch lights up to
indicate power to the unit. The unit may not come on right away due to the timer built into the
circuiting to prevent compressor short cycling.

Testing the Fan

Refer to thermostat manufactures instructions on how to change the fan settings from ON to
AUTO.
 ON means the fan runs continuously and indicates that the power is on and
the control circuit is energized and operating.
 AUTO means the fan runs only when the thermostat is calling for cooling,
heating, or the humidistat is calling for humidification.

Running the Unit

 Check unit to confirm the compressor is running, such as the hum of the compressor or
cool air leaving the unit.
 Check for any unusual noise or vibration, such as clanking or rubbing.
Initially, the unit may run continuously for several hours, up to a day or more, while it lowers the
room temperature. Once the unit reaches the setpoint temperature, it shuts off and starts to cycle
on and off as it continues to lower the bottle temperature to the setpoint. The room air reaches set
point before the bottles. If the room temperature started at 75 degrees the supply air temperature
discharged from the unit will probably be 15 degrees to 20 degrees colder. As the room
temperature decreases to 55 degrees, the supply temperature differential decreases 8 to 12 degrees
colder.
CAUTION
RISK OF PERSONAL INJURY
INSIDE THE UNIT.