VKI Technologies Eccellenza cafe Service Manual page 60

Eccellenza cafe
Table of Contents

Advertisement

Eccellenza Café – Service Manual
4. On the main valve body, twist the ground tab clockwise to free the plunger housing,
and pull it away from the main valve body. This exposes the plunger and assembly.
Be careful not to lose the small spring inserted into the end of the plunger.
5. Pull the plunger assembly out of the main valve body. This exposes the
diaphragm installed onto the tip of the plunger.
6. Remove the diaphragm by pulling it off of the tip of the plunger. The spring on
the other end of the plunger can also be removed.
To re-assemble the outlet valve, follow these same instructions, but in the reverse
order.
60
August 5, 2013

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents