Eccellenza Café – Service Manual
Sanitization – Flavor Pumps and Tubes
Should the flavoring system ever require sanitization, the following procedure must
be performed. Please note that safety goggles and latex gloves should be worn at all
times throughout this procedure.
NOTE: When ready for use, the end-use concentration of all quaternary
chemicals in the solution is not to exceed 200ppm of active quaternary
compound.
1.
Remove the disposable flavor bottles from their supports.
2.
Remove the silicone bottle caps from the bottles and completely immerse
them in sanitizing solution (2ml of S.C. Johnson J-512 Sanitizer per one liter
of water) for approximately 5 minutes.
3.
Discard the old flavor bottles and their contents. These bottles must never be
re-used for any purpose!
4.
Fill a spray bottle with a solution of J-512 Sanitizer and clean water (2ml of
sanitizer per liter of water) and thoroughly spray the outside of the flavor
tubes (bottle side) with the sanitizing solution. Do not wipe the solution.
5.
Fill three empty and clean flavor bottles (minimum 250 ml) with S.C. Johnson
J-512 Sanitizer (2ml of S.C. Johnson J-512 Sanitizer per one liter of water).
Fill the remainder of the bottles with clean water (up to the neck of the
bottles). Do not install a silicone cap onto the bottles.
6.
Place the bottles (without caps) onto their supports and insert the respective
tubing into each of the bottles.
7.
Place a leak-proof container (one liter capacity) directly underneath the
dispensing spouts.
Press the "Rinse Cycle" button on the inside of the front door.
8.
Press "Sanitize FL Pumps" on the front selection panel to activate the
9.
automated sanitizing procedure. All three pumps will cycle continuously until all of
the solution in the bottles has run through the flavor system.
10. Remove the three empty bottles and rinse them thoroughly with potable water.
11. Once rinsed, fill the three bottles with potable water. Place the bottles (again
without caps) onto their supports and insert the respective tubing into each
of the bottles.
12. Press the "
automated rinsing procedure. All three pumps will cycle continuously until all
of the clean water in the bottles has run through the flavor system, rinsing any
remaining sanitizing solution in the process.
14
NOTE: If three empty flavor bottles are not available, you can use a clean
one liter container (with 2ml of sanitizer per one liter of clean water). Insert
all three inlet flavor tubes into this one container of sanitizing solution.
" button on the front selection panel to activate the
START