Operation Panel; Names And Functions Of The Operation Panel - Mitsubishi Electric FR-D700 Instruction Manual

Hide thumbs Also See for FR-D700:
Table of Contents

Advertisement

Operation panel

4.1
Operation panel
4.1.1

Names and functions of the operation panel

The operation panel cannot be removed from the inverter.
Operation mode indication
PU: Lit to indicate PU operation mode.
EXT: Lit to indicate external operation
mode.
NET: Lit to indicate network operation
mode.
PU, EXT: Lit to indicate external/PU
combined operation mode 1, 2.
Unit indication
Hz: Lit to indicate frequency.
A: Lit to indicate current.
(Off to indicate voltage and flicker to
indicate set frequency monitor.)
Monitor (4-digit LED)
Shows the frequency, parameter number,
etc.
Setting dial
(Setting dial: Mitsubishi inverter dial)
Used to change the frequency setting
and parameter values.
Press to display the following.
Displays the set frequency in the
monitor mode
Currently set value is displayed during
calibration
Displays the order in the faults history
mode
Mode switchover
Used to change each setting mode.
Pressing
simultaneously changes
the operation mode. (Refer to page 54)
Pressing for a while (2s) can lock
operation.
(Refer to page 261)
Determination of each setting
If pressed during operation, monitor
changes as below;
Running frequency
Output current
Output voltage
48
Operating status display
Lit or flicker during inverter operation.
* On:
Indicates
that
forward
operation is being performed.
Slow flickering (1.4s cycle):
Reverse rotation operation
Fast flickering (0.2s cycle):
When
was pressed or the start
command was given, but the operation
can not be made.
When the frequency command is less
than the starting frequency.
When the MRS signal is input.
Parameter setting mode
Lit to indicate parameter setting mode.
Monitor indication
Lit to indicate monitoring mode.
Stop operation
Used to stop Run command.
Fault can be reset when protective
function is activated (fault).
Operation mode switchover
Used to switch between the PU and
external operation mode.
When using the external operation mode
(operation using a separately connected
frequency setting potentiometer and start
signal), press this key to light up the EXT
indication.
(Press
simultanesouly (0.5s) (Refer
to page 54), or change Pr. 79 setting to
change to combined mode .)
PU: PU operation mode
EXT: External operation mode
Cancels PU stop also.
Start command
The rotation direction can be selected by
setting Pr. 40.
rotation