Frequency setting by analog input (terminal 2, 4)
4.16.3 Bias and gain of frequency setting voltage (current)
(Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905))
You can set the magnitude (slope) of the output frequency as desired in relation to the frequency setting signal (0 to 5V,
0 to 10V or 4 to 20mADC).
Set Pr. 267 and voltage/current input switch to switch between 0 to 5VDC, 0 to 10VDC, 0 to 20mADC using terminal 4.
(Refer to page 145)
[Frequency setting bias/gain parameter]
Parameter
Number
Terminal 2 frequency setting
125
gain frequency
Terminal 4 frequency setting
126
gain frequency
Analog input display unit
241 ∗1, ∗3
switchover
C2 (902)
Terminal 2 frequency setting
∗1, ∗2
bias frequency
C3 (902)
Terminal 2 frequency setting
∗1, ∗2
bias
C4 (903)
Terminal 2 frequency setting
∗1, ∗2
gain
C5 (904)
Terminal 4 frequency setting
∗1, ∗2
bias frequency
C6 (904)
Terminal 4 frequency setting
∗1, ∗2
bias
C7 (905)
Terminal 4 frequency setting
∗1, ∗2
gain
∗1
The above parameters can be set when Pr. 160 Extended function display selection = "0". (Refer to page 157)
∗2
The parameter number in parentheses is the one for use with the operation panel (PA02) for the FR-E500 series or parameter unit (FR-PU04/FR-PU07).
∗3
The above parameters allow its setting to be changed during operation in any operation mode even if "0" (initial value) is set in Pr. 77 Parameter write selection.
148
Initial
Name
Value
50Hz
50Hz
0
0Hz
0%
100%
0Hz
20%
100%
Setting
Range
0 to 400Hz
Frequency of terminal 2 input gain (maximum).
0 to 400Hz
Frequency of terminal 4 input gain (maximum).
0
Displayed in %
1
Displayed in V/mA
0 to 400Hz
Frequency on the bias side of terminal 2 input.
Converted % of the bias side voltage (current) of
0 to 300%
terminal 2 input.
Converted % of the gain side voltage (current) of
0 to 300%
terminal 2 input.
0 to 400Hz
Frequency on the bias side of terminal 4 input.
Converted % of the bias side current (voltage) of
0 to 300%
terminal 4 input.
Converted % of the gain side current (voltage) of
0 to 300%
terminal 4 input.
Description
Unit for analog input display.