Mitsubishi Electric FR-D700 Instruction Manual page 166

Hide thumbs Also See for FR-D700:
Table of Contents

Advertisement

Selection of operation mode and operation location
(2) Operation mode switching method
When "0 or 1" is set in Pr. 340
Switching from the network
Switch to the external
operation mode from
the network.
Network operation
When "10" is set in Pr. 340
Network operation
REMARKS
Refer to the flow chart on the next page for switching by the external terminal.
PU operation external interlock signal (X12)
PU-external operation switch-over signal (X16)
External-NET operation switchover signal (X65), NET-PU operation switchover signal (X66)
Pr. 340 Communication startup mode selection
162
External operation
Switch to network operation
mode from the network.
Press
of the PU to light
Press
of the PU to light
Refer to page 166
Refer to page 167
Refer to page 170
Switching from the PU
Press
the PU to light
Press
of
the PU to light
Refer to page 168
of
PU operation
PU operation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents