3.2.3 PU operation mode
(Operation using the operation panel (FR-DU04))
( 1 ) Operation at 60Hz
While the motor is running, repeat the following steps 2 and 3 to vary the speed:
Step
Power-on → Operation mode check
Switch power on and make sure that the operation command
indication "PU" is lit.
1
(If it is not lit, switch to the PU operation mode.)
Running frequency setting
Set the running frequency to 60Hz.
First, press the [MODE] key to select the frequency setting mode.
2
Then, press the [UP/DOWN] key to change the setting, and press
the [SET] key to write the frequency.
Start
Press the [FWD] or [REV] key.
The motor starts running. The monitoring mode is automatically
3
selected and the output frequency is displayed.
Stop
Press the [STOP] key.
The motor is decelerated to a stop.
4
( 2 ) PU jog operation
Hold down the [FWD] or [REV] key to perform operation, and release it to stop.
1) Set Pr. 15 "jog frequency" and Pr. 16 "jog acceleration/deceleration".
2) Select the PU jog operation mode.
3) Hold down the [FWD] or [REV] key to perform operation.
(If the motor remains stopped, check Pr. 13 "starting frequency". The motor will not start if its setting is
lower than the starting frequency.)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
55
OPERATION
Image
ON
REV
FWD
(or)
FR-DU04
CONTROL PANEL
Hz
A
V
MON
EXT
PU
REV
FWD
(or)
FWD
REV
REV
FWD
FR-DU04
CONTROL PANEL
Hz
A
V
MON
EXT
PU
REV
FWD

Advertisement

Table of Contents
loading

Table of Contents