Mitsubishi Electric FR-D700 Instruction Manual page 257

Hide thumbs Also See for FR-D700:
Table of Contents

Advertisement

Operation panel
E.PUE
indication
Name
PU disconnection
This function stops the inverter output if communication between the inverter and PU is suspended, e.g. the
parameter unit (FR-PU04/FR-PU07) is disconnected, when "2", "3", "16" or "17" was set in Pr. 75 Reset selection/
disconnected PU detection/PU stop selection.
This function stops the inverter output when communication errors occurred consecutively for more than permissible
Description
number of retries when a value other than "9999" is set in Pr. 121 Number of PU communication retries during the RS-
485 communication with the PU connector (use Pr. 502 Stop mode selection at communication error to change).
This function also stops the inverter output if communication is broken within the period of time set in Pr. 122 PU
communication check time interval during the RS-485 communication with the PU connector.
Check that the parameter unit cable is fitted tightly.
Check the Pr. 75 setting.
Check point
Check that RS-485 communication data is correct. And check that the settings of communication parameter at
inverter match settings of the computer.
Check that data is transmitted from the computer within a time set in Pr. 122 PU communication check time interval.
Connect the parameter unit cable securely.
Corrective action
Check the communication data and communication settings.
Increase the Pr. 122 PU communication check time interval setting. Or set "9999" (no communication check).
Operation panel
E.RET
indication
Name
Retry count excess
If operation cannot be resumed properly within the number of retries set, this function trips the inverter.
Description
Functions only when Pr. 67 Number of retries at fault occurrence is set.
When the initial value (Pr. 67 = "0") is set, this protective function does not function.
Check point
Find the cause of fault occurrence.
Corrective action
Eliminate the cause of the error preceding this error indication.
Operation panel
E.CPU
indication
Name
CPU fault
Description
Stops the inverter output if the communication fault of the built-in CPU occurs.
Check point
Check for devices producing excess electrical noises around the inverter.
Take measures against noises if there are devices producing excess electrical noises around the inverter.
Corrective action
Please contact your sales representative.
Operation panel
E.CDO
indication
Name
Output current detection value exceeded
Description
This function is activated when the output current exceeds the Pr. 150 Output current detection level setting.
Check the settings of Pr. 150 Output current detection level, Pr. 151 Output current detection signal delay time, Pr. 166 Output
Check point
current detection signal retention time, Pr. 167 Output current detection operation selection. (Refer to page 119)
Operation panel
E.IOH
indication
Name
Inrush current limit circuit fault
Description
This function is activated when the resistor of the inrush current limit circuit overheats. The inrush current limit circuit fault
Check point
Check that frequent power ON/OFF is not repeated.
Configure a circuit where frequent power ON/OFF is not repeated.
Corrective action
If the problem still persists after taking the above measure, please contact your sales representative.
Operation panel
E.AIE
indication
Name
Analog input fault
Description
Appears when 30mA or more is input or a voltage (7.5V or more) is input with the terminal 4 set to current input.
Check point
Check the setting of Pr. 267 Terminal 4 input selection and voltage/current input switch. (Refer to page 145).
Either give a frequency command by current input or set Pr. 267 Terminal 4 input selection, and voltage/current input
Corrective action
switch to voltage input.
NOTE
If protective functions of E.ILF, E.AIE, E.IOH, E.PTC, E.CDO are activated when using the FR-PU04, "Fault 14" is
displayed.
Also when the faults history is checked on the FR-PU04, the display is "E.14".
If faults other than the above appear, contact your sales representative.
Causes and corrective actions
FR-PU04
PU Leave Out
FR-PU07
FR-PU04
Retry No Over
FR-PU07
FR-PU04
CPU Fault
FR-PU07
FR-PU04
Fault 14
FR-PU07
OC detect level
FR-PU04
Fault 14
FR-PU07
Inrush overheat
FR-PU04
Fault 14
FR-PU07
Analog in error
5
253

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents