Xstatus Systemunit Hardware Audioboard Identifier; Xstatus Systemunit Hardware Audioboard Serialnumber; Xstatus Systemunit Hardware Bootsoftware; Xstatus Systemunit Hardware Monitoring Fan [1 - Cisco TelePresence System Codec C90 Reference Manual

Software version tc5.0
Hide thumbs Also See for TelePresence System Codec C90:
Table of Contents

Advertisement

Cisco TelePresence System Codec C90
Contents
Introduction

xStatus SystemUnit Hardware AudioBoard SerialNumber

Shows the serial number of the audio board in the codec.
Value space of the result returned:
<S: 0, 100>
Example:
xStatus SystemUnit Hardware AudioBoard SerialNumber
*s SystemUnit Hardware AudioBoard SerialNumber: "N/A"
** end

xStatus SystemUnit Hardware AudioBoard Identifier

Shows the revision of the audio board in the codec.
Value space of the result returned:
<S: 0, 100>
Example:
xStatus SystemUnit Hardware AudioBoard Identifier
*s SystemUnit Hardware AudioBoard Identifier: ""
** end

xStatus SystemUnit Hardware BootSoftware

Shows the version of the boot software that is installed on the codec.
Value space of the result returned:
<S: 0, 100>
Example:
xStatus SystemUnit Hardware BootSoftware
*s SystemUnit Hardware BootSoftware: "U-Boot 2010.04-30"
** end

xStatus SystemUnit Hardware MonitoringSoftware

The feedback will show the monitoring software id.
Value space of the result returned:
<Integer value>
Example:
xstatus SystemUnit Hardware MonitoringSoftware
*s SystemUnit Hardware MonitoringSoftware: "39"
** end
D14641.06
Codec C90 API Reference Guide TC5.0 November 2011.
© 2010-2011 Cisco Systems, Inc. All rights reserved.
About the API
xConfiguration
xStatus SystemUnit Hardware Monitoring Fan [1..n] Status

xStatus SystemUnit Hardware Temperature

xStatus SystemUnit State System

153
xCommand
The feedback will show the speed (rpm) for the specified fan.
Value space of the result returned:
<S: 0, 100>
Example:
xstatus SystemUnit Hardware Monitoring Fan 1 Status
*s SystemUnit Hardware Monitoring Fan 1 Status: "locked on 1096 rpm"
** end
The feedback will show the current maximum temperature (degree Celsius) measured in the codec/
system.
Value space of the result returned:
<Double (decimal) number>
Example:
xstatus SystemUnit Hardware Temperature
*s SystemUnit Hardware Temperature: "64.0"
** end
Shows what state the system is in.
InCall: The system is in a call.
Initialized: The system is ready for use.
Initializing: The system is initializing.
Multisite: The system is in a Multisite conference.
Sleeping: The system is in sleep mode.
Value space of the result returned:
<InCall/Initialized/Initializing/Multisite/Sleeping>
Example:
xStatus SystemUnit State System
*s SystemUnit State System: Initialized
** end
API Reference Guide
xStatus
xStatus
Appendices
www.cisco.com

Advertisement

Table of Contents
loading

Table of Contents