Digital Operator Monitor Display - Saftronics FP5 Series User Manual

Table of Contents

Advertisement

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor
A-2 DIGITAL OPERATOR MONITOR DISPLAY
The following table describes the contents of the digital operator monitor
display.

Digital Operator Monitor Display

Name
(LCD Operator Display)
Frequency Reference
(Frequency Ref)
Output Frequency
(Output Freq)
Output Current
(Output Amps)
Output Power
(Output Power)
FWD/REV Run Command
(Forward/Reverse)
Monitor
(Monitor U-XX)
FP5/GP5 User's Manual
Digital Operator Monitor Display
Description
· Frequency reference can be monitored/set.
· Setting/display unit depends on display mode (n023).
· Output frequency is displayed.
· Display unit depends on display mode (n023).
Output current is displayed in units of 0.1A (1A for 1,000A and above).
Output power is displayed in units of 0.1kW (1kW for 1,000kW and
above).
· FWD/REV run command can be monitored/set.
· Setting enabled during run command from digital operator.
· FWD run displays "Forward", REV run displays "Reverse".
The following conditions can be monitored.
No. Contents
U-01 Frequency reference
U-02 Output frequency
U-03 Output current
U-04 Output voltage reference is displayed in units of 1V.
U-05 DC voltage is displayed in units of 1V.
U-06 Output power
Input terminal status is displayed (terminals S1 to S6).
_ 11 11 11
U-07
Inverter status is displayed.
11
1 11 11
-
U-08
Appendix A-2
1: S1 closed
1: S2 closed
1: S3 closed
1: S4 closed
1: S5 closed
1: S6 closed
Always blank
1: During run
1: Reverse run
1: Inverter ready
1: Fault
1: MODBUS error
Always blank
1: MA-MC output OFF
1: M1-M2 output OFF