No.
Function Name
(LCD Operator Display)
n034 Motor thermal protection
(Motor OL Sel)
n035 Stop method selection -
OH1- for inverter
overheat pre-alarm
(OH1 Stop Method)
n036 Multi-function input selec-
tion 1
(Terminal S2 Sel)
FP5/GP5 User's Manual
Chapter 3 - Programming Features
FP5/GP5 Parameters
Description
LED Setting
LCD Setting
Description
0
Disabled
Protection disabled
1
STD Motor/8 min
General-purpose motor (time
constant 8 min.)
2
STD Motor/5 min
General-purpose motor (time
constant 5 min.)
3
INV Motor/8 min
Blower-cooled motor (time
constant 8 min.)
4
INV Motor/ 5 min
Blower-cooled motor (time
constant 5 min.)
LED Setting
LCD Setting
Description
0
Ramp STOP/Decel 1 Ramp to stop - Decel 1
(fault)
1
Coast to STOP
Coast to stop (fault)
2
Ramp STOP/Decel 2 Ramp to stop - Decel 2
(fault)
3
Continue Oper
Continue operation
(alarm) at 80% of fre-
quency reference
LED
LCD
Setting Setting
Description
0
Reverse RUN (2W)
Reverse run (2-wire sequence)
1
FWD/REV Cmd (3W) Fwd / Rev command (3-wire sequence)
2
Ext Fault (NO)
External fault (normally open)
3
Ext Fault (NC)
External fault (normally closed)
4
Fault Reset
Fault reset
5
LOCAL/REMOTE Sel Local / Remote selection
6
COM/INV Sel
Serial com/inverter selection (Fref, RUN
command)
7
STOP Cmd/Dec2 NO Fast stop using Decel 2 (normally open)
8
STOP Cmd/Dec2 NC Fast stop using Decel 2 (normally
closed)
9
Master Fref Sel
Master freq. ref. selection (FV-open or
FI-closed)
10
Multi-Step Spd 1
Multi-step speed reference command 1
11
Multi-Step Spd 2
Multi-step speed reference command 2
12
Not Used
Not used
13
JOG Command
Jog reference (n030)
14
Acc/Dec Switch
Accel / Decel time selection
15
Ext Baseblk (NO)
External baseblock (normally open)
16
Ext Baseblk (NC)
External baseblock (normally closed)
17
SpdSrch (MAXFRQ) Speed search from maximum fre-
quency
18
SpdSrch (SETFRQ) Speed search from set frequency
19
Param Lockout
Parameter setting enable / disable
20
PID I Reset
PID integral value reset
21
PID Disable
PID control enable / disable
22
Timer Start Cmd
Timer function
23
OH3 Input
External overheat alarm (OH3)
24
Ref Sample Hold
Analog reference sample hold com-
mand
25
KEB Cmd (NO)
Inertia ridethrough command (normally
open)
26
KEB Cmd (NC)
Inertia ridethrough command (normally
closed)
27
Hold Command
Accel / Decel hold command
28
PID Polarity Sel
Inverse PID enable / disable
Factory
User
Ref.
Default
Setting
Page
STD
62
Motor/
8 min
-
Continue
Oper
Reverse
78
RUN
(2W)