FP5/GP5 Parameters
No.
Function Name
(LCD Operator Display)
n014 Mid. output frequency
(Mid Frequency)
n015 Mid. frequency voltage
(Mid Voltage)
n016 Minimum output
frequency
(Min Frequency)
n017 Minimum output voltage
(Min Voltage)
n018 Acceleration time 1
(Accel Time 1)
n019 Deceleration time 1
(Decel Time 1)
n020 Acceleration time 2
(Accel Time 2)
n021 Deceleration time 2
(Decel Time 2)
n022 S-curve selection
(S-Curve Select)
n023 Display mode
(Display Units)
n024 Frequency reference 1
(Reference 1)
n025 Frequency reference 2
(Reference 2)
n026 Frequency reference 3
(Reference 3)
n027 Frequency reference 4
(Reference 4)
n028 Not used
n029 Not used
n030 Jog frequency
(Jog Reference)
n031 Frequency upper limit
(Ref Upper Limit)
n032 Frequency lower limit
(Ref Lower Limit)
n033 Motor rated current
(Motor Rated FLA)
42
Description
Unit: 0.1Hz
Setting range: 0.1~399.9Hz
Unit: 0.1V
Setting range: 0.1~255.0V (510V for 460V units)
Unit: 0.1Hz
Setting range: 0.1~10.0Hz
Unit: 0.1V
Setting range: 0.1~50.0V (510V for 460V units)
Unit: 0.1s (1s for 1000s and above)
Setting range: 0.0~3600s
Unit: 0.1s (1s for 1000s and above)
Setting range: 0.0~3600s
Unit: 1s
Setting range: 0~255s
Unit: 1s
Setting range: 0~255s
LED Setting
LCD Setting
0
No S-curve
1
0.2s
2
0.5s
3
1.0s
Setting
Display
0
0.1Hz
1
0.1%
2~39
rpm (input # of motor poles)
40~3999
custom
Setting depends on n023 setting.
Range: 0~9999
Setting depends on n023 setting.
Range: 0~9999
Setting depends on n023 setting.
Range: 0~9999
Setting depends on n023 setting.
Range: 0~9999
-
-
Setting depends on n023 setting.
Range: 0~9999
Unit: 1%
Setting range: 0~109%
Unit: 1%
Setting range: 0~100%
Unit: 0.1A Range: 10~200% inverter rated current
Unit is 1A, when setting is more than 1,000A
FP5/GP5 User's Manual
Factory
User
Ref.
Default
Setting
Page
3Hz
76
17.2V
76
(34.4V)
1.5Hz
76
11.5V
76
(23.0V)
10.0s
50,96
10.0s
50,96
10.0s
50
10.0s
50
0.2s
68
0
-
0.0Hz
64,95
0.0Hz
64
0.0Hz
64
0.0Hz
64
-
-
-
-
-
-
6.0Hz
60
100%
69
0%
69
kVA
62,96