Fp5/Gp5 Parameters (N001~N116); Description - Saftronics FP5 Series User Manual

Table of Contents

Advertisement

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor

3.1 FP5/GP5 Parameters (n001~n116)

No.
Function Name
(LCD Operator Display)
n001 Parameter selection/
initialization
(Password)
n002 Operation mode selection
(Oper Mode Select)
n003 Input voltage
(Input Voltage)
n004 Stopping method
(Stopping Method)
n005 Motor rotation
(Motor Rotation)
n006 Prohibit reverse operation
(Reverse Oper)
n007 Local/remote key function
(Local/Remote Key)
n008 Stop key function
(Oper STOP Key)
n009 Frequency reference set-
ting method from operator
(Operator MOP)
n010 V/f pattern selection
(V/f Selection)
n011 Maximum frequency
(Max Frequency)
n012 Maximum voltage
(Max Voltage)
n013 Base frequency
(Base Frequency)
FP5/GP5 User's Manual
Chapter 3 - Programming Features
FP5/GP5 Parameters

Description

0: n001 read and set, n002~n116 read only
1: n001~n035 read and set, n036~n116 read only
2: n001~n053 read & set, n054~n116 read only
3: n001~n116 read and set
4, 5: Not used
6: 2-wire initialization (Japanese specifications)
7: 3-wire initialization (Japanese specifications)
8: 2-wire initialization (American specifications)
9: 3-wire initialization (American specifications)
LED Setting
LCD Setting
Operation
0
SEQ=OPR REF=OPR
Operator
1
SEQ=TRM REF=OPR
Terminal
2
SEQ=OPR REF=TRM
Operator
3
SEQ=TRM REF=TRM
Terminal
4
SEQ=OPR REF=COM
Operator
5
SEQ=TRM REF=COM
Terminal
6
SEQ=COM REF=COM
Serial com
7
SEQ=COM REF=OPR
Serial com
8
SEQ=COM REF=TRM
Serial com
Unit: 0.1V
Setting range: 150.0~255.0V (510V for 460V units)
LED Setting
LCD Setting
Description
0
Ramp to stop
Ramp to stop
1
Coast to stop
Coast to stop
2
Coast w/Timer1
Coast to stop with timer
(Run command cycle)
3
Coast w/Timer2
Coast to stop with timer
(auto-start after time out)
LED Setting
LCD Setting
Description
0
Rotate C.C.W.
CCW shaft rotation
1
Rotate C.W.
CW shaft rotation
LED Setting
LCD Setting
Description
0
Rev Allowed
Reverse operation enabled
1
Rev Prohibited
Reverse operation disabled
LED Setting
LCD Setting
0
Disabled
1
Enabled
LED Setting
LCD Setting
Description
0
Disabled
Stop key is disabled when
operated from terminals
1
Enabled
Stop key is always enabled
LED Setting
LCD Setting
0
Enter not used
1
Enter key used
LED Setting
LCD Setting
Description
0
User Defined V/f
Custom V/f pattern
(n011 ~ n017 can be set)
1
60 Hz Preset
Fixed V/f pattern
Unit: 0.1Hz
Setting range: 50.0~400.0Hz
Unit: 0.1V
Setting range: 0.1~255.0V (510V for 460V units)
Unit: 0.1Hz
Setting range: 0.2~400.0Hz
Factory
User
Ref.
Default
Setting
Page
1
49
Reference
SEQ=TRM
37
Operator
REF=TRM
Operator
Terminal
Terminal
Serial com
Serial com
Serial com
Operator
Terminal
230.0V
-
(460.0V)
Ramp to
70
Stop
Rotate
-
C.C.W.
Rev
68
Allowed
Enabled
37
Enabled
-
Enter
-
key
used
75,96
60 Hz
Preset
60.0Hz
76
230.0V
76
60.0Hz
76
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp5 series

Table of Contents