Saftronics FP5 Series User Manual page 91

Table of Contents

Advertisement

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor
LCD
Operator-
Fault
Display
* CE
MODBUS transmission
Modbus
fault
Com Err
Control circuit fault 1
CPF0
(CPFO)
Com-Err
Digital operator
(Op +Inv)
transmission fault
Control circuit fault 2
CPF1
(CPF1)
Com-Err
Digital operator
(Op +Inv)
transmission fault
CPF4
EEPROM fault (CPF4)
Eprom
Error
CPF5
CPU A/D converter fault
External
(CPF5)
A/O Err
rr
Regenerative brake transis-
Dyn Brk
tor failure
Trans
h
Dynamic brake resistor
r
overheat (DB resistor over-
Dyn Brk
load)
Res
P
o
r
Operator
LCD operator disconnected The LCD operator has been disconnected
Failure
CPF5
EPROM
Parameter read/write error EPROM life cycle has been exceeded
R/W Err
* Stopping method selection is available for these faults.
FP5/GP5 User's Manual
Name
Description
Control data cannot be received nor-
mally.
· Transmission between the inverter and
digital operator cannot be established 5
seconds after supplying power.
· MPU peripheral element check fault
(on-line)
· Transmission between the inverter and
digital operator is established once
after supplying power, but later trans-
mission fault continues for more than 2
seconds.
· MPU peripheral element check fault
(on-line).
Inverter PCB control board fault.
Dynamic braking transistor has failed
Dynamic brake resistor duty cycle value
exceeded (>3% ED)
Chapter 4 - Diagnostics
Alarm & Fault Displays
Corrective Action
Check the transmission
devices or signals.
· Insert the digital operator
connector again.
· Check the control circuit
wiring.
· Replace the control card.
· Insert the digital operator
connector again.
· Check the digital control
circuit wiring.
· Replace the control card.
Replace the control card.
· Check dynamic brake
resistance.
· Check for proper wiring of
dynamic brake resistor.
· Replace power board.
· Check for excessive load.
· Increase deceleration time.
· Increase time between
decelerations.
· Check LCD operator wiring.
· Check parameter n110
· Check control card wiring.
· Replace the control card.