Operation Checkpoints; Basic Operation - Saftronics FP5 Series User Manual

Table of Contents

Advertisement

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor
Chapter 2 - Operation
Trial Operation

Operation Checkpoints:

· Motor rotates smoothly.
· Motor rotates in the correct direction.
· Motor has no abnormal vibration and is not noisy.
· Acceleration and deceleration are smooth.
· Unit is not overloaded.
· Status indicator LEDs and digital operator display are correct.

Basic Operation

The inverter will operate after receiving a frequency reference. There are
two operation modes for the FP5/GP5:
· Run command from the digital operator.
· Run command from the control circuit terminals.
Operation by Digital Operator
The diagram below shows a typical operation pattern using the digital
operator. Pressing the LOCAL/REMOTE key once while the inverter is
stopped places the inverter in the LOCAL mode. The digital operator,
JVOP-130P, can then be used to start and stop and change the reference.
1
Power
ON
32
4
2
3
Forward
15Hz
Forward Run
Reverse Run
Frequency Setting
Frequency Reference Change
Figure 15 Operation Sequence by Digital Operator
5
6
Stop
Reverse
60Hz
FP5/GP5 User's Manual