FP5/GP5 Parameters
No.
Function Name
(LCD Operator Display)
n065 Elapsed timer selection
(Elapsed Timer)
n066 Elapsed timer 1
(Elapsed Time 1)
n067 Elapsed timer 2
(Elapsed Time 2)
n068 DC injection current
(DCInj Current)
n069 DC injection time at stop
(DCInj Time @ Stop)
n070 DC injection time at start
(DCInj Time @ Start)
n071 Torque compensation
gain
(Torq Comp Gain)
n072 Stall prevention during
deceleration
(StallP Decel Sel)
n073 Current limit/Stall preven-
tion level during accelera-
tion
(StallP Accel Lvl)
n074 Current limit/Stall preven-
tion level during running
(StallP Run Level)
n075 Frequency agree set point
(Freq Det Level)
n076 Frequency agree
detection width
(Freq Det Width)
n077 Over/Undertorque
detection OL3
(Torq Det Sel)
46
Description
LED
Setting
LCD Setting
Description
0
Time Power is ON Accumulate time during power on
1
Time Running Mtr Accumulate time during running
Unit: 1 hour
Range: 0~9999
* Initial value becomes 0 only when initialized dur-
ing CPF4 occurrence.
Unit: 10,000 hours
Range: 0~27
* Initial value becomes 0 only when initialized dur-
ing CPF4 occurrence.
Unit: 1%
Setting range: 0~100%
100% = inverter rated current
Unit: 0.1s
Setting range: 0.0~10.0s
Unit: 0.1s
Setting range: 0.0~10.0s
Unit: 0.1
Setting range: 0.0~3.0
(normally, no adjustment is necessary)
LED
Setting
LCD Setting
0
Disabled
1
Enabled
Unit: 1% Setting range: 30~200%
When level is set to 200%, current limit during
acceleration is disabled.
Unit: 1% Setting range: 30~200%
When level is set to 200%, current limit during
running is disabled.
Unit: 0.1Hz
Setting range: 0.0~400.0Hz
Unit: 0.1Hz
Setting range: 0.0~25.5Hz
LED
Setting LCD Setting
Description
0
Disabled
Detection disabled
1
OT/Spd Agree/Alm Overtorque detection at speed agree;
continue running after detection.
(Alarm)
2
OT/Run/Alm
Overtorque detection at run; continue
running after detection. (Alarm)
3
OT/Spd Agree/Flt Overtorque detection at speed agree;
coast to stop after detection. (Fault)
4
OT/Run/Flt
Overtorque detection at run; coasts to
stop after detection. (Fault)
5
UT/Spd Agree/Alm Undertorque detection at speed
agree; continue running after detec-
tion. (Alarm)
6
UT/Run/Alm
Undertorque detection at run; con-
tinue running after detection. (Alarm)
7
UT/Spd Agree/Flt Undertorque detection at speed
agree; coast to stop after detection.
(Fault)
8
UT/Run/Flt
Undertorque detection at run; coast to
stop after detection. (Fault)
FP5/GP5 User's Manual
Factory
User
Ref.
Default
Setting
Page
Time
-
Running
Mtr
*
-
*
-
50%
54,75
0.0s
54
0.0s
55,75
1.0
72
Enabled
54
kVA
52
dependent
kVA
53
dependent
0.0Hz
57,84
2.0Hz
84
73
Disabled