Reverse Run Prohibit; Soft-Start Characteristics - Saftronics FP5 Series User Manual

Table of Contents

Advertisement

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor
Chapter 3 - Programming Features
FP5/GP5 Operation
Reverse Run Prohibit (n006, Reverse Oper)
A "reverse run disabled" setting does not accept a reverse run command
from the control circuit terminal or the digital operator. This setting is
used in applications where a reverse run command can cause problems.
LED Setting
0
1
Soft-Start Characteristics (n022, S-Curve Select)
An S-curve pattern is used to reduce shock and provide smooth transitions
during machine acceleration and deceleration.
LED Setting
0
1
2
3
Note: The S-curve time is the time to reach the set accel/decel rate (as determined by the accel/
decel time settings).
Frequency Reference
Output Frequency
68
LCD Setting
REV Allowed
Reverse run enabled (factory default)
REV Prohibited
LCD Setting
No S-Curve
S-curve not provided
0.2 Sec
0.2 second (factory default)
0.5 Sec
1.0 Sec
Output Frequency
S-curve Characteristic
Time (Tsec)
Figure 36 S-curve Characteristic Timing Diagram
Description
Reverse run disabled
Description
0.5 second
1.0 second
Time