4.1 MAINTENANCE & INSPECTION
This section describes basic maintenance and inspection procedures for
the FP5/GP5.

Periodic Inspection

The FP5/GP5 will function longer if it is kept clean, cool and dry,
and if all precautions highlighted in this manual are observed. Periodi-
cally inspect the inverter as described in the table below to prevent acci-
dents and to ensure high performance with high reliability.
To prevent electrical shock, disconnect all power before servicing the
inverter. Then wait at least five minutes after the power supply is discon-
nected and all LEDs are extinguished.
Component
External Terminals,
Connectors, Mounting
Screws, etc.
Heatsink
Printed Circuit Board
(PCB)
Cooling Fan
Power Components
Smoothing Capacitor Discoloration or odor

Parts Replacement Schedule

Replace the following parts periodically, for long, safe, trouble-free oper-
ation of the FP5/GP5:
Parts
Cooling Fan
Smoothing Capacitor
Breakers or Relays
Fuses
Aluminum Electrolytic
Capacitor on PCB Board
FP5/GP5 User's Manual
Check
Loose screws or connectors
Build-up of dust and dirt
Accumulation of conductive dust or
oil
For abnormal noise and vibration
Accumulation of dust and dirt
Approximate Interval
2 to 3 years
Replace with new one.
5 years
Replace with new one (after inspection).
--
Decide after inspection.
10 years
Replace with new one.
5 years
Replace with new one (after inspection).
Chapter 4 - Diagnostics
Maintenance & Inspection
Corrective Action
Securely tighten.
Blow with dry, compressed air [39.2
4
4
2
× 10
to 58.8 × 10
Pa (4 to 6kg·cm
pressure].
Blow with dry, compressed air [39.2
4
4
2
× 10
to 58.8 × 10
Pa (4 to 6kg·cm
pressure]. If dust and oil cannot be
removed, replace the board.
Replace the cooling fan.
Blow with dry, compressed air [39.2
4
4
× 10
to 58.8 × 10
Pa (4 to 6kg·cm2)
pressure].
Replace the capacitor or the inverter.
Remarks