Saftronics FP5 Series User Manual page 63

Table of Contents

Advertisement

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor
· General-purpose and Blower-cooled Motors
Induction motors are classified as general-purpose or blower-cooled
motors, based on their cooling capabilities. Hence, the motor overload
detection function operates differently for each of these two motor types.
Cooling Effectiveness
Effective when operated at
50/60Hz from commercial
power supply.
Effective when operated at
low speeds (approx. 6Hz).
FP5/GP5 User's Manual
Chapter 3 - Programming Features
FP5/GP5 Operation
Torque Characteristics
180
155
60s
140
Short time
Standard
100
Rating
80
55
38
0
3
20
60
120
Frequency (Hz)
Base Frequency 60Hz
(V/f for 60Hz, 230V Input Voltage)
During continuous operation at low
speeds, the load must be limited in
order to limit motor temperature rise.
180
60s
150
Short time
Standard
100
Rating
55
38
0
6
60
120
Frequency (Hz)
Base Frequency 60Hz
(V/f for 60Hz, 230V Input Voltage)
Use blower-cooled motor for contin-
uous operation at low speeds.
Electronic Thermal
Overload
"OL1" error (motor overload
protection is enabled when
motor is continuously oper-
ated at 50/60Hz or less at
100% load).
Effective when operated at
low speeds (approx. 6Hz).
63