Saftronics FP5 Series User Manual page 45

Table of Contents

Advertisement

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor
No.
Function Name
(LCD Operator Display)
n047 Frequency reference level
at loss of Fref
(Fref Lvl@F Loss)
n048 Terminal FV gain
(Terminal FV Gain)
n049 Terminal FV bias
(Terminal FV Bias)
n050 Terminal FI gain
(Terminal FI Gain)
n051 Terminal FI bias
(Terminal FI Bias)
n052 Multi-function analog
output AM
(Terminal AM Sel)
n053 Analog monitor gain
(Terminal AM Gain)
n054 Carrier frequency
(Carrier Freq Sel)
n055 Momentary power loss
ridethrough method
(PwrL Selection)
n056 Speed search level -
decel time fixed at 2 sec
(SpdSrch Current)
n057 Minimum baseblock time
(Min Baseblock t)
n058 V/f reduction level during
speed search
(SpdSrch V/f)
n059 Power loss ridethrough
time
(PwrL Ridethru t)
n060 Automatic retry attempts
(Num of Restarts)
n061 Fault contact selection
during automatic retry
(Restart Sel)
n062 Jump frequency 1
(Jump Freq 1)
n063 Jump frequency 2
(Jump Freq 2)
n064 Jump frequency
bandwidth
(Jump Bandwidth)
FP5/GP5 User's Manual
Chapter 3 - Programming Features
FP5/GP5 Parameters
Description
Unit: 1%
Setting range: 0~100% of setting Fref
Unit: 1%
Setting range: 0~200%
Unit: 1%
Setting range: -100~100%
Unit: 1%
Setting range: 0~200%
Unit: 1%
Setting range: -100~100%
LED
Setting
LCD Setting
Monitor
0
Output Freq
Output frequency
1
Output Amps
Output current
2
Output kWatts
Output power
3
DC Bus Voltage
DC bus voltage
Unit: 0.01
Setting range: 0.01~2.00
Unit: 1
Setting range: 1~6 (x2.5kHz), 7~9 (custom pattern)
LED
LCD
Setting
Setting
Method
0
Not Provided
Not provided
1
2 Seconds Max
Continuous operation after
power recovery within 2s
2
CPU Power Active
Continuous operation after
power recovery within control
logic time (no fault output)
Unit: 1% Setting range: 0~200%
100% = inverter rated current
Unit: 0.1s
Setting range: 0.5~10.0s
Unit:1%
Setting range: 0~100%
Unit: 0.1s
Setting range: 0.0~2.0s
Unit: 1 time
Setting range: 0~10
LED
Setting
LCD Setting
Description
0
Activate Flt Rly
Closed during fault retry
1
No Rly Output
Open during fault retry
Unit: 0.1Hz
Setting range: 0.0~400.0Hz
Unit: 0.1Hz
Setting range: 0.0~400.0Hz
Unit: 0.1Hz
Setting range: 0.0~25.5Hz
Factory
User
Ref.
Default
Setting
Page
80%
82
100%
59,96
0%
59,96
100%
59
0%
59
Output
58
Freq
1.00
58
kVA
51
dependent
Not
51
Provided
110%
74
kVA
71
dependent
kVA
-
dependent
kVA
-
dependent
0
51
Activate
-
Flt Rly
0.0Hz
60
0.0Hz
60
1.0Hz
60
45