Chapter 3 - Programming Features
FP5/GP5 Parameters
No.
Function Name
(LCD Operator Display)
n037 Multi-function input 2
(Terminal S3 Sel)
n038 Multi-function input 3
(Terminal S4 Sel)
n039 Multi-function input 4
(Terminal S5 Sel)
n040 Multi-function input 5
(Terminal S6 Sel)
n041 Multi-function output
selection 1
(Terminal MA Sel)
n042 Multi-function output
selection 2
(Terminal M1 Sel)
n043 Master analog input selec-
tion - FV or FI terminal
(Analog Input Sel)
n044 Aux. analog input
selection
(Terminal FI Sel)
n045 Frequency reference
retention
(MOP Ref Memory)
n046 Operation method for
frequency reference
loss detection
(Ref Loss Detect)
44
Description
Set items are same as n036.
(When n036="FWD/REV Cmd (3W), "In Use By
Other" is displayed, and setting is prohibited)
Set items are same as n036.
Set items are same as n036.
(When n040="Up/Down Control", "In Use By Other
is displayed, and setting is prohibited)
Set items are same as n036.
LED
Setting
LCD Setting
Description
29
Up / Down control Up / Down command (Terminal
S5=Up command, and terminal
S6=Down command).
LED
Setting
LCD Setting
Description
0
Fault
Fault
1
During Running
During running
2
At Speed
Frequency agree
3
At Desired Speed
Desired frequency agree
4
Freq Detection 1
Frequency detection 1
5
Freq detection 2
Frequency detection 2
6
OverTrq Det (NO)
Over/Undertorque detection (nor-
mally open)
7
OverTrq Det (NC)
Over/Undertorque detection (nor-
mally closed)
8
Baseblocked
During baseblock
9
Operation Mode
Local mode
10
Ready
Inverter operation ready
11
Timer Output
Timer function
12
Auto-Restarting
During auto restart
13
OL Pre-Alarm
OL pre-alarm (80% OL1 or OL2)
14
Freq Ref Loss
Frequency reference loss
15
Set By COM Cntl
Closed by serial communication
16
PID Fdbk Loss
PID feedback loss
17
OH1 Alarm
OH1 Alarm (set if n035 set to "3")
Set items are as same as n041
LED
LCD
Setting Setting
FV
FI
0
FV=MSTR FI=AUX
Master
Aux.
1
FV=AUX
FI=MSTR Aux.
Master
2
FV=RST
FI=MSTR Fault reset Master
Enable:
FV/FI switchover function is enabled.
Disable:
FV/FI switchover function is disabled.
Note: When PID is enabled (n084 ≠ 0),
FV terminal = PID reference, and
FI terminal = PID feedback.
LED
Setting
LCD Setting
Description
0
0-10VDC
0~10V input (Jumper J1 must be cut)
1
4-20mA
4~20mA input
LED
Setting
LCD Setting
Description
0
Memorize Fref
Retained in frequency reference 1 (n024)
1
Not Memorized Not retained after power-down
LED
Setting
LCD Setting
Description
0
Not detected
No detection
1
Run @ n047 Fref
Continue to run at n047 setting
FP5/GP5 User's Manual
Factory
User
Ref.
Default
Setting
Page
Ext
78
Fault
(NO)
Fault
78
Reset
Multi-
78
Step
Spd 1
Multi-
78
Step
Spd 2
Fault
83
During
83
Running
FV=MSTR
82
Remarks
FI=AUX
Enable
Enable
Disable
4-20mA
82
Memorize
82
Fref
Not
82
Detected