3. Position adjustment

Set DIP switch 2 on the scanner to "ON."
Adjusting offset (origin)
(1)
Start the software. (See p. 10-1)
(2)
Select "Adjust Position" from the "Adjust" menu.
(3)
The following dialog box will appear: Correctly position the test chart on the scanner and click the
"Scan" button.
Use the cursor or keys to enter a value to
adjust level differences between the image sensors.
Values actually used for adjustment
Press the Calculate button to calculate these values.
(4)
The following dialog box will appear: Click the "Scan" button.
CS1000-UM-251-02-9370
Use the cursor or keys to enter
the position of the origin.
10-8
10. ADJUSTMENTS WITH SOFTWARE
Scan conditions:
"Document Info"
Paper Size: JIS A0
(CS1100: JIS A1)
Document Type:
Black and White
Resolution: 600 dpi
"Scan Settings"
Output: Bilevel
Intensity: 115
Intensity Correction: 0
Edge Adjustment: 0