General purpose corded handheld linear bar code reader (37 pages)
Summary of Contents for Datalogic QuickScan QD2430
Page 1
QuickScan™ QD2430 General Purpose Corded Handheld Area Imager Bar Code Reader Quick Reference Guide...
Page 2
Datalogic has taken reasonable measures to provide informa- tion in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A.
2. Scope Of License Granted. 2.1 Datalogic grants to End User a non-exclusive, non-transferable, perpetual license to use the Software, solely on the Datalogic Product in which it is embedded ("designated Datalogic Product"), in machine-readable form only, solely for End User's internal business purposes. This Agreement does not convey ownership of the Software to End User.
Page 6
Datalogic or Datalogic's third party licensors and that the Software is protected by intellectual property laws and treaties. The license set forth in this Agreement does not transfer to End User any ownership of Datalogic' s or its third party licen- sors' copyrights, patents, trademarks, service marks, trade secrets, or other intel- lectual property rights and End User shall have no right to commence any legal actions to obtain such rights.
Page 7
Datalogic ADC, Inc., Legal Department, 959 Terry Street, Eugene, OR 97402. 7.2 In the defense or settlement of any such claim, Datalogic may, at its option, 1) procure for End User the right to continue using the Datalogic Product, 2)
Notices to Datalogic shall be sent to the attention of Contract Administration, Datalogic ADC, Inc., 959 Terry Street, Eugene, OR 97402, or such other address as may be specified by Datalogic in writing.
Ele- gant design details are incorporated into a smaller, balanced lightweight enclosure without sacrificing Datalogic' s well- known durability. Ideally suited for applications at the point-of-sale (POS), the...
Setting Up the Reader Reliably decodes all standard 1D (linear) and 2D bar codes, including GS1 DataBar™ linear codes, Postal Codes (China Post), Stacked Codes (such as GS1 DataBar Expanded Stacked, GS1 DataBar Decoding Stacked, GS1 DataBar, Stacked Omnidirectional). The data stream — acquired from decoding a sym- bol —...
Using the Quickscan™ QD24XX Figure 2. Connecting to the Host Side View Using the Quickscan™ QD24XX The Quickscan™ QD24XX normally functions by capturing and decoding codes. The aiming system is activated on trigger pull and indicates the center of the field of view which should be positioned over the bar code: Aiming System Relative Size and Location of Aiming System Pattern...
LED indicator. Reference the QuickScan QD24XX Product Reference Guide (PRG) on the Datalogic website for more information about this feature and other programmable settings. Selecting the Interface Type...
Selecting the Interface Type Configuring the Interface Scan the appropriate programming bar code to select the interface type for your system. Unlike some other programming features and options, interface selections require that you scan only one programming bar code label. DO NOT scan an ENTER/EXIT bar code prior to scan- ning an interface selection bar code.
USB Com to simulate RS-232 standard interface Select USB-COM-STD USB-OEM USB-OEM (can be used for OPOS/UPOS/JavaPOS) Select USB-OEM a. Download the correct USB Com driver from www.datalogic.com Keyboard Interface Use the programming bar codes to select options for USB Keyboard and Wedge Interfaces. KEYBOARD AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 &...
Page 15
Selecting the Interface Type KEYBOARD (continued) AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key Select KBD-AT-ALT Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard Select KBD-AT-ALT-NK PC/XT w/Standard Key Encoding Select KBD-XT Keyboard Wedge for IBM Terminal 3153 Select KBD-IBM-3153...
Page 16
Selecting the Interface Type KEYBOARD (continued) USB Keyboard with alternate key encoding Select USB Alternate Keyboard USB Keyboard for Apple computers Select USB-KBD-APPLE Keyboard Wedge for DIGITAL Terminals VT2xx, VT3xx, VT4xx Select KBD-DIG-VT USB Keyboard with standard key encoding Select USB Keyboard QuickScan™...
Selecting the Interface Type Scancode Tables Reference the QuickScan QD2430 PRG for information about control character emulation for keyboard interfaces. Country Mode This feature specifies the country/language supported by the keyboard. Only these interfaces support ALL Country Modes: • USB Keyboard (without alternate key encoding) •...
Page 18
Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Croatia* Country Mode = Czech Republic* Country Mode = Denmark* Country Mode = France $CKBCO13(CR) Country Mode = French Canadian* Country Mode = Germany *Supports only the interfaces listed in the Country Mode feature description QuickScan™...
Page 19
Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Hungary* Country Mode = Italy Country Mode = Japanese 106-key* Country Mode = Lithuanian* Country Mode = Norway* Country Mode = Poland* *Supports only the interfaces listed in the Country Mode feature description Quick Reference Guide...
Page 20
Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Portugal* Country Mode = Romania* Country Mode = Spain Country Mode = Sweden Country Mode = Slovakia* Country Mode = Switzerland* *Supports only the interfaces listed in the Country Mode feature description QuickScan™...
Selecting the Interface Type Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected. CAPS LOCK STATE ENTER/EXIT PROGRAMMING MODE Caps Lock State = Caps Lock OFF Caps Lock State = Caps Lock ON...
Selecting the Interface Type Numlock This option specifies the setting of the Numbers Lock (Num- lock) key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard. NUMLOCK ENTER/EXIT PROGRAMMING MODE Numlock = Numlock key unchanged Numlock = Numlock key toggled QuickScan™...
Programming Programming The reader is factory-configured with a set of standard default features. After scanning the interface bar code from the Interfaces section, select other options and customize your reader through use of the programming bar codes avail- able in the QuickScan QD24XX PRG. Check the corresponding features section for your interface, and also the Data Editing and Symbologies chapters of the PRG.
Reading Parameters Reading Parameters Move the reader toward the target and center the aiming pat- tern and illumination system to capture and decode the image. See Using the Quickscan™ QD24XX on page 3 for more information. The aiming system will briefly switch off after the acquisition time, and if no code is decoded will switch on again before the next acquisition.
Operating Modes Operating Modes Scan Mode The imager can be set to operate in one of several scanning modes. See the PRG for more information and settings for any of the options: Trigger Single (Default) — This mode is associated with typical handheld reader operation.
Operating Modes Pick Mode Specifies the ability of the reader to decode labels only when they are close to the center of the aiming pattern, which is the area indicated by the two blue arrows. Pick Mode is a Decod- ing and Transmission process where bar codes that are not within the configurable distance from the center of the aiming pattern are not acknowledged or transmitted to the host.
Technical Specifications Technical Specifications The following table contains Physical and Performance Char- acteristics, User Environment and Regulatory information. Item Description Physical Characteristics Color Black & white Height 6.4"/163 mm Dimensions Length 3.6"/91 mm Width 1.6"/41 mm Weight (without cable) Approximately 5.1 ounces/145 g Electrical Characteristics Input Voltage: 4.5 - 14.0VDC Operating (typical): 140mA...
LED and Beeper Indications Contaminants Spray/rain IEC 529-IP42 Dust/particulates (IP51 QD2430-E model only) ESD Level 16 KV Regulatory Electrical Safety UL 60950, CSA C22.2 No. 60950, IEC 60950 North America (FCC) : Part 15 Class B; Canada ( IC) : ICES- 003 Class B;...
Page 32
LED and Beeper Indications Indicator Description Beeper Reader 'chirps' six Indicates that a host Limited Scanning times at the highest connection is not Label Read frequency and current established. volume. The reader is active and Reader Active Mode The LED is lit steadily ready to scan.
LED and Beeper Indications Programming Mode - The following indications ONLY occur when the reader is in Programming Mode. INDICATION DESCRIPTION BEEPER Label Programming A valid programming label LED blinks contin- Reader sounds four Mode Entry has been scanned. uously low frequency beeps.
Error Codes Error Codes Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is reset, the sequence will be repeated. Press and release the trigger to hear the FRU indication code.
Cleaning Cleaning Exterior surfaces and scan windows exposed to spills, smudges or debris require periodic cleaning to ensure best performance during scanning. Use a soft, dry cloth to clean the product. If the product is very soiled, clean it with a soft cloth moistened with a diluted non- aggressive cleaning solution or diluted ethyl alcohol.
Any changes or modifications to equipment, not expressly approved by Datalogic could void the user' s authority to oper- ate the equipment. Statement of Agency Compliance This device complies with part 15 of the FCC Rules. Operation...
Regulatory Information Canadian Notice This equipment does not exceed the Class B limits for radio noise emissions as described in the Radio Interference Regu- lations of the Canadian Department of Communications. Le present appareil numerique n’emet pas de bruits radio- electriques depassant les limites applicables aux appareils numeriques de la classe B prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Commu-...
Regulatory Information Imager Labeling Sample labels are shown here to illustrate their location only. Please view the labels on your product for actual details, as they may vary from those depicted. Scanner Regulatory The QuickScan™ Handheld Reader is not user- serviceable.
Spanish Si desea información acerca de los procedimientos para el desecho de los residuos del equipo eléctrico y electrónico (WEEE), visite la página Web www.datalogic.com. Portuguese Para informações sobre a disposição de Sucatagem de Equipamentos Elétricos e Eletrônicos (WEEE -Waste Electrical and Electronic Equipment), consultar o site web www.datalogic.com.
90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period, whichever is longer. Da-...
Datalogic. Datalogic shall assume risk of loss or damage for product in Datalogic’s possession. In the absence of specific written instruc- tions for the return of product to Customer, Datalogic will select the carrier, but Datalogic shall not thereby assume any liability in connec- tion with the return shipment.
Ergonomic Recommendations Ergonomic Recommendations In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety CAUTION Manager to ensure that you are adhering to your company’s safety programs to prevent employee injury.
Services and Support Services and Support Datalogic provides several services as well as technical sup- port through its website. Log on to www.datalogic.com click on the links indicated for further information. Products Search through the links to arrive at your product page where...
Page 45
Services and Support NOTES Quick Reference Guide...
Page 46
Services and Support NOTES QuickScan™ QD2430...
La presente dichiarazione di conformità è rilasciata sotto la responsabilità esclusiva di Datalogic ADC Srl per: This Declaration of Conformity is issued under the sole responsibility of Datalogic ADC Srl for: Cette déclaration de conformité est établie sous la seule responsabilité de Datalogic Srl pour: Diese Konformitätserklärung wird unter der alleinigen Verantwortung des Datalogic ADC...
Need help?
Do you have a question about the QuickScan QD2430 and is the answer not in the manual?
Questions and answers