Installing The Dc Reactor - Toshiba TOSVERT VF-AS1 Instruction Manual

High-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

1.3.4 Installing the DC reactor

When purchasing and installing a DC reactor (DCL1, packaged with the inverter for 400V-355kW to 500kW models),
refer to the table below.
Applicable DC reactor types
Inverter
VFAS1-2550P
VFAS1-2750P
VFAS1-4900PC
VFAS1-4110KPC
VFAS1-4132KPC
VFAS1-4160KPC
VFAS1-4200 KPC
VFAS1-4220KPC /4280KPC
VFAS1-4355 KPC /4400KPC
VFAS1-4500KPC
How to install (Example: VFAS1-4160KPC)
(1)
Front cover
Remove the front cover and the top cover.
(3)
Connect the reactor unit to the PO and
PA/+ terminals on the main-circuit
terminal board. Then connect the
supplied earth wire.
⇒ See the figures on the next page.
Fix the front cover after connecting.
DC reactor type
DCL1-2550
DCL1-2750
DCL1-4900
DCL1-4110K
DCL1-4132K
DCL1-4160K
DCL1-4200K
DCL1-4280K
Included with the inverter
Included with the inverter
Top cover
A-15
(2)
Reactor unit
Mount the reactor case on an inner wall of
the cabinet and secure the reactor unit to
the case with screws.
(4)
Top panel
Cover
Front panel
Secure the cover, front panel and top panel
to the reactor case with screws.
E6581445
1
Reactor case

Advertisement

Table of Contents
loading

Table of Contents