Braking Function - Toshiba TOSVERT VF-AS1 Instruction Manual

High-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

6. 17

Braking function

 : Braking mode selection
 : Load portion torque input
selection
 : Hoisting torque bias input
 : Lowering torque bias multiplier
• Function
These parameters can be used as brake sequences for lifts and similar equipment.
To ensure smooth operation, the motor produces enough torque before the brake is released.
Title
Braking mode selection


Load portion torque input selection
Hoisting torque bias input (valid

only when =)
Lowering torque bias multiplier

Brake release time

Creeping frequency

Creeping time

Braking time learning function

Starting procedure
At the run command, the inverter makes the motor produce the torque specified with parameter . As soon as
a torque output command is issued, a brake release request signal is put out through the brake output terminal.
Upon expiration of the brake release time set with , the motor starts to accelerate.
Function
:Disabled
:Forward winding up
:Reverse winding up
:Horizontal operation
:Disabled
:VI/II (voltage/current input)
:RR/S4 (potentiometer/voltage input)
:RX (voltage input)
: enabled
:2-wire RS485 input enabled
:4-wire RS485 input enabled
:Communications option input enabled
:Optional AI1 (differential current input)
-~ %
~ %
~ sec.
~ Hz
~ sec.
:Disabled
:Brake signal learning (0 after adjustment)
F-29
 : Brake release time
 : Creeping frequency
 : Creeping time
 : Braking time learning function
Adjustment range
E6581445
Default setting
6




