Toshiba TOSVERT VF-AS1 Instruction Manual page 265

High-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

[19] Torque control [2/2]
Communi
Title
cation
Function
No.
Forward speed limit input
0425

selection

0426
Forward speed limit input level
Reverse speed limit input

0427
selection
0428
Reverse speed limit input level

Speed limit (torque = 0) center

0430
value reference selection
Speed limit (torque = 0) center
0431

value

0432
Speed limit (torque = 0) band
Prohibition of rotation in any

0435
direction other than the specified
one (F or R)
*1: ⇒ For details, refer to Instruction Manual (E6581331) specified in Section 6.42.
[20] Torque limit [1/2]
Communi
Title
cation
Function
No.
Power running torque limit 1
0440

selection
Power running torque limit 1

0441
level
Regenerative braking torque
0442

limit 1 selection
Adjustment range
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4: enabled
0.0~ Hz
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4: enabled
0.0~ Hz
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4: enabled
0.0~ Hz
0.0~ Hz
0:Disabled
1:Enabled
Adjustment range
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
0.0~249.9%, 250.0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Enabled
-
0.1/0.01

Enabled
-
1/1
0
Enabled
-
0.1/0.01
Enabled
-

1/1
0
Enabled
-
0.1/0.01
0.0
Enabled
-
0.1/0.01
0.0
Enabled
-
1/1
0
Enabled
-
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
4
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
1/1
4
Enabled
●/●
PM
Torque
V/f Constant Reference
control
control
●/●
-
-
*1
●/●
-
-
*1
●/●
-
-
*1
●/●
-
-
*1
●/●
-
-
*1
●/●
-
-
*1
●/●
-
-
*1
●/●
-
-
*1
PM
Torque
V/f Constant Reference
control
control
●/●
-
6. 25. 1
●/●
-
6. 25. 1
●/●
-
6. 25. 1