Toshiba TOSVERT VF-AS1 Instruction Manual page 259

High-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

[10] Jump frequency
Communi
Title
cation
Function
No.

0270
Jump frequency 1

0271
Jumping width 1

0272
Jump frequency 2

0273
Jumping width 2

0274
Jump frequency 3

0275
Jumping width 3
[11] Preset speed operation frequency (8~15)
Communi
Title
cation
Function
No.
Preset speed operation

0287
frequency 8
Preset speed operation
0288

frequency 9
Preset speed operation

0289
frequency 10
Preset speed operation

0290
frequency 11
Preset speed operation

0291
frequency 12
Preset speed operation
0292

frequency 13
Preset speed operation
0293

frequency 14
Preset speed operation

0294
frequency 15
(Forced operation frequency)
[12] Tripless intensification setup [1/2]
Communi
Title
cation
Function
No.
0300
PWM carrier frequency

0301
Auto-restart control selection

Regenerative power ride-
0302

through control

0303
Retry selection
This parameter moves to a fundamental parameter.
*2: Default values vary depending on the capacity. ⇒ See the table of K-46.
Adjustment range
0.0~ Hz
0.0~30.0Hz
0.0~ Hz
0.0~30.0Hz
0.0~ Hz
0.0~30.0Hz
Adjustment range
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
Adjustment range
1.0~16.0kHz (2.5~8.0kHz) *1
0:Disabled, 1:At auto-restart
2:ST ON/OFF switching, 3:1+2, 4:Starting
0:Disabled, 1:Power ride-through
2:Deceleration stop during power failure
3:Synchronized deceleration/acceleration
(synchronized acceleration/deceleration signal)
4:Synchronized deceleration/acceleration
(synchronized acceleration/deceleration signal+power failure)
0:Deselect, 1-10 times
*1: For 200V-55/75kW models and 400V-90kW to 400V-500kW models, the carrier frequency is between 2.5 and 8.0kHz inclusive.
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
Write during
setting unit
Default
running
Speed
(Panel/Communi
setting
control
cation)
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
setting
running
(Panel/Communi
control
cation)
0.1/0.1
*2
Enabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Enabled
●/●
PM
Torque
V/f
Reference
control
control
-
6. 12
-
6. 12
-
6. 12
-
6. 12
-
6. 12
-
6. 12
PM
Torque
V/f
Reference
control
control
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
PM
V/f
Reference
Torque
control
control
●/●
5. 17
●/●
5. 18.1
-/-
5. 18. 2
●/●
6. 14. 1

Advertisement

Table of Contents
loading

Table of Contents