[24] Protection functions [2/3]
Communi
Title
cation
Function
No.
Selection of short circuit
0613
detection at starting
0615
Overtorque trip selection
Overtorque detection level
0616
during power running
Overtorque detection level
0617
during regenerative braking
0618
Overtorque detection time
0619
Overtorque detection hysteresis 0~100%
0620
Cooling fan control selection
Cumulative operation time alarm
0621
setting
0622
Abnormal speed detection time
Overspeed detection frequency
0623
upper band
Overspeed detection frequency
0624
lower band
0625
Undervoltage detection level
0626
Overvoltage limit operation level 100~150%
0627
Undervoltage trip selection
Undervoltage (trip alarm)
0628
detection time
Regenerative power ride-through
0629
control level
0630
Braking answer waiting time
0631
Temperature detection
VI/II analog input wire breakage
0633
detection level
Annual average ambient
temperature (calculation for part
0634
replacement alarms)
Rush current suppression relay
0635
activation time
Adjustment range
0:Each time (standard pulse)
1:Only one time after power is turned on
2:Each time (short pulse)
3.Only one time after power is turn on (short pulse)
4:Each time (Extremely shot-time pulse)
5.Only one time after power is turn on (Extremely
shot-time pulse)
0:No trip
1:Trip
0~250%
0~250%
0.00~10.00 sec.
0:Auto
1:Always ON
0.1~999.9 (x100h)
0.01~100.0 sec.
0.0:Disabled, 0.1~30.0Hz
0.0:Disabled, 0.1~30.0Hz
50~79%, 80: (auto mode)
0:Disabled
1:Enabled
0.01~10.00 sec.
55~100%
0.0:Disabled, 0.1~10.0 sec.
0:Standard (150%-60 sec.)
1:Estimation of temperature
0:None
1~100%
1:-10~+10°C
2:+11~+20°C
3:+21~+30°C
4:+31~+40°C
5:+41~+50°C
6:+51~+60°C
0.0~2.5 sec.
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
●/●
1/1
0
Enabled
●/●
1/0.01
150
Enabled
●/●
1/0.01
150
Enabled
●/●
0.01/0.01
0.50
Enabled
●/●
1/0.01
10
Enabled
●/●
1/1
0
Enabled
●/●
0.1/0.1
610.0
Enabled
●/●
0.01/0.01
0.01
Enabled
-/●
0.1/0.01
0.0
Enabled
-/●
0.1/0.01
0.0
Enabled
-/●
1/1
80
Disabled
●/●
1/1
134
Disabled
●/●
1/1
0
Disabled
●/●
0.01/0.01
0.03
Disabled
●/●
1/1
75
Disabled
●/●
0.1/0.1
0.0
Enabled
●/●
1/1
0
Disabled
-
1/1
0
Enabled
●/●
1/1
3
Enabled
●/●
0.1/0.1
0.0
Disabled
●/●
PM
Torque
V/f Constant Reference
control
control
●/●
●
●
6. 33. 9
●/●
●
●
6. 33. 10
●/●
●
●
6. 33. 10
●/●
●
●
6. 33. 10
●/●
●
●
6. 33. 10
●/●
●
●
6. 33. 10
●/●
●
●
6. 33. 11
●/●
●
●
6. 33. 12
●/●
-
-
6. 33. 13
●/●
-
-
6. 33. 13
●/●
-
-
6. 33. 13
●/●
●
●
6. 33. 15
-
●
●
6. 14. 2
●/●
●
●
6. 33. 15
●/●
●
●
6. 33. 15
●/●
●
●
6. 33. 16
-
-
-
6. 33. 17
-
-
-
5. 14
●/●
●
●
6. 33. 18
●/●
●
●
6. 33. 19
●/●
●
●
6. 33. 20