Toshiba TOSVERT VF-AS1 Instruction Manual page 258

High-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

[7] Operation frequency
Communi
Title
cation
Function
No.

0240
Starting frequency setting

0241
Operation start frequency
Operation start frequency
0242

hysteresis
0243
Stop frequency setting

Frequency command dead
0244

band
[8] DC braking
Communi
Title
cation
Function
No.

0250
DC braking start frequency

0251
DC braking current

0252
DC braking time
Forward/reverse DC braking
0253

priority control
0254
Motor shaft fixing control

0255
0Hz command output selection

Time limit for lower-limit

0256
frequency operation
[9] Jogging operation
Communi
Title
cation
Function
No.
0260
Jog run frequency

0261
Jog run stop pattern


0262
Operation panel jog run mode
Input from external contacts -

0264
UP response time
Input from external contacts -

0265
UP frequency step
Input from external contacts -
0266

DOWN response time
Input from external contacts -
0267

DOWN frequency step

0268
Initial UP/DOWN frequency
Initial up/down frequency

0269
rewriting
Adjustment range
0.0~10.0Hz
0.0~ Hz
0.0~30.0Hz
0.0~30.0Hz
0.0~5.0Hz
Adjustment range
0.0~120.0Hz
0~100%
0.0~20.0 sec.
0:Disabled, 1:Enabled
0:Disabled, 1:Enabled
0:Default (DC braking)
1:0Hz command
0.0:Disabled
0.1~600.0 sec.
Adjustment range
~20.0Hz
0:Deceleration stop
1:Coast stop
2:DC braking stop
0:Disabled
1:Operation panel jog run mode enabled
0.0~10.0 sec.
0.0~ Hz
0.0~10.0 sec.
0.0~ Hz
~ Hz
0:Not changed
1:Setting of  changed when power is
turned off
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
0.1/0.01
0.1
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
0.1/0.01
0.0
Enabled
●/●
1/1
50
Enabled
●/●
0.1/0.1
1.0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
-/●
0.1/0.1
0.0
Enabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
0.1/0.01
5.0
Enabled
●/●
1/1
0
Disabled
●/●
1/1
0
Enabled
●/●
0.1/0.1
0.1
Enabled
●/●
0.1/0.01
0.1
Enabled
●/●
0.1/0.1
0.1
Enabled
●/●
0.1/0.01
0.1
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
1/1
1
Enabled
●/●
PM
Torque
V/f
Reference
control
control
-
6. 7. 1
-
6. 7. 2
-
6. 7. 2
-
6. 7. 1
-
6. 7. 3
PM
Torque
V/f
Reference
control
control
-
6. 8. 1
-
6. 8. 1
-
6. 8. 1
-
6. 8. 1
-
6. 8. 2
-
6. 8. 3
●/●
6. 9
PM
V/f
Reference
Torque
control
control
-
6. 10
-
6. 10
-
6. 10
-
6. 11
-
6. 11
-
6. 11
-
6. 11
-
6. 11
-
6. 11