[27] Operation panel parameters [1/3]
Communi
Title
cation
Function
No.
Parameter write protect
0700
selection
0701
Current/voltage unit selection
Frequency free unit display
0702
magnification
Frequency free unit conversion
0703
selection
Free unit display gradient
0705
characteristic
0706
Free unit display bias
0707
Changing step selection 1
0708
Changing step selection 2
0709
Standard monitor hold function
Standard monitor display
0710
selection
Status monitor 1 display
0711
selection
Status monitor 2 display
0712
selection
Status monitor 3 display
0713
selection
Status monitor 4 display
0714
selection
Status monitor 5 display
0715
selection
Status monitor 6 display
0716
selection
Status monitor 7 display
0717
selection
Status monitor 8 display
0718
selection
Operation command clear
0719
selection when standby terminal
(ST) is OFF
Operation panel stop pattern
0721
selection
Operation panel torque
0725
command
Operation panel tension torque
0727
bias
Operation panel load sharing
0728
gain
Operation panel override
0729
multiplication gain
Operation panel frequency
0730
setting prohibition selection
This parameter moves to a fundamental parameter. *1: ⇒ For the adjustment range, see the table on page K-39.
Adjustment range
0:Permit
1:Prohibit
0:%, 1:A (ampere)/V (volt)
0.00:OFF, 0.01~200.0
0:All frequencies display free unit conversion
1:PID frequencies free unit conversion
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
0.00~ Hz
0.00:Disabled, 0.01~ Hz
0:Disabled, 1~255
0:Real time, 1:Peak hold, 2:Minimum hold
0~70 *1
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
0:Clear operation command
1:Retain operation command
0:Deceleration stop
1:Coast stop
-250~250%
-250~250%
0~250%
-100~100%
0:Permit
1:Prohibit
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
1/1
0
Enabled
●/●
1/1
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
0.01/0.01
0.00
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
1
Enabled
●/●
1/1
2
Enabled
●/●
1/1
3
Enabled
●/●
1/1
4
Enabled
●/●
1/1
8
Enabled
●/●
1/1
16
Enabled
●/●
1/1
15
Enabled
●/●
1/1
14
Enabled
●/●
1/1
1
Enabled
●/●
1/1
0
Enabled
●/●
1/0.01
0
Enabled
-
1/0.01
0
Enabled
-
1/0.01
100
Enabled
-
1/0.01
0
Enabled
●/●
1/1
0
Enabled
●/●
PM
Torque
V/f Constant Reference
control
control
●/●
●
●
6. 36. 1
●/●
●
●
5. 15
●/●
●
●
6. 36. 2
●/●
●
●
6. 36. 2
●/●
●
●
6. 36. 2
●/●
●
●
6. 36. 2
●/●
●
●
6. 36. 3
●/●
●
●
6. 36. 3
●/●
●
●
8. 3
●/●
●
●
8. 3
●/●
●
●
8. 3
●/●
●
●
8. 3
●/●
●
●
8. 3
●/●
●
●
8. 3
●/●
●
●
8. 3
●/●
●
●
8. 3
●/●
●
●
8. 3
●/●
●
●
8. 3
●/●
●
●
6. 36. 5
●/●
●
●
6. 36. 6
●/●
-
-
6. 36. 7
●/●
-
-
6. 36. 8
●/●
-
-
6. 36. 8
-
●
●
6. 34
●/●
●
●
6. 36. 1