Basic Parameters; Table Of Parameters; History Function - Toshiba TOSVERT VF-AS1 Instruction Manual

High-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

5. Basic parameters

This parameter is a basic parameter for the operation of the inverter.
⇒ Refer to Section 11, Table of parameters.
5.1

History function

: History function

• Function
Automatically searches for 5 latest parameters that are programmed with values different from
the standard default setting and displays them in the . Parameter setting can also be
changed within this group .
This function comes in very handy when you adjust the inverter repeatedly using the same
parameter.
Note 1: If no history information is stored, this parameter is skipped and the next parameter .
Note 2:  and  are added respectively to the first and last parameters in a history of changes.
[Setting methods]
Key operated
MODE
ENT
ENT
ENT
(
(
MODE
MODE
MODE
LED display
Displays the operation frequency (operation stopped).
(When standard monitor display selection =

[Output frequency])
The first basic parameter "History function ()" is

displayed.
The parameter that was set or changed last is displayed.

Press the ENTER key to display the set value.


Press the
Press the ENTER key to save the changed value. The
parameter name and the programmed value will flash on
⇔
and off alternately.
Use the same steps as those given above to display
)
****
parameters that you want to search for or change setting
with the
: First historic record

)
()
 : Last historic record
Parameter display
Press the MODE key to return to the parameter setting
mode .

After that you can press the MODE key to return to the
status monitor mode or the standard monitor mode (display

of operation frequency).

Operation
key and
key to change set value.
key and
key.
E-1
E6581445
5