Horizontal Termination

Minimum vertical rise from the top exit position
is a 24" section vent pipe. See fig. 10.
A horizontal vent run made directly off the rear of
the stove must terminate ONLY with a 36" Snor-
kel Cap.
The maximum horizontal run shall include
no more than a single 24" section of pipe.
See figs. 11 and 11a.
A single 45° Elbow may be used to offset the
vent for a corner installation as in fig. 11.
The termination cap must not be recessed into
the wall or siding. Do not fill air space in wall
around termination cap with any type of insula-
tion.
Wall Cut-out: A minimum 10" X 10" square hole
is adequate for proper pipe clearance through a
wall, provided the vent is positioned to maintain
2" minimum clearance at the top. A 1" minimum
clearance must be maintained to combustible
material around the other sides.
Maximum Wall Thickness: 14 in. (356 mm)
Any horizontal run of vent must be level or have a
1/4" rise for every foot of run toward the termina-
tion cap.
Installation of a Vinyl Siding Standoff is required
to prevent damage to vinyl siding between the
vent cap and the exterior wall.
The horizontal termination cap must maintain a
3" clearance to any overhead combustible projec-
tions that are 2 1/2" or less. It must also maintain
a 12" clearance from projections that exceed 2 1/2".
See fig. 13.
Figure 11. Rear Exit Corner Termination, only into a
36" Snorkel. Maximum horizontal run is 24"
(610 mm) with one 45° Elbow.
Vertical Termination:
Max. 35’ 10.67 m
Min. 7’ 2.13 m
Figure 10. A vertical run in a horizontal termination
must be at least 2 feet (61 cm).
Fig. 12
Figure 11a. Rear Exit Horizontal Termination, only into
a 36" Snorkel. Maximum horizontal run is 24" (610
mm).
Min. 6”
Max. 16”
Min.
24”
610 mm
36”
Snorkel
Rear Exit
24 "
Position
610 mm
138090_Rev_F
7.29.10
Max. Horizontal
run 10 ft. after
min. 10 ft.
(305 cm)
Vertical Rise
Standard Horizontal Termi-
nation Cap
C L
Min.
58 1/2”
1486 mm
C L
27 3/4”
705 mm
36" Snorkel
Termination
11