Jøtul GF 3 BF 3 Installation And Operation Instructions Manual

Balanced flue gas stove

Advertisement

Installation and

Operation Instructions

WARNING: If the information in
these instructions is not followed
exactly, a fire or explosion may
result causing property damage,
personal injury or death.
– Do not store or use gasoline or
other flammable vapors and liq-
uids in the vicinity of this or any
other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical
switch; do not use any phone in
your building.
• Immediately call your gas
supplier from a neighbor's phone.
Follow the gas supplier's
instruction.
• If you cannot reach your gas
supplier, call the fire department.
– Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
139405_A CF 3 BF 3
1

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul GF 3 BF 3

  • Page 1: Operation Instructions

    139405_A CF 3 BF 3 Installation and Operation Instructions WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. – Do not store or use gasoline or other flammable vapors and liq- uids in the vicinity of this or any other appliance.
  • Page 2: Limited Warranty

    Jøtul Group Gas Product 139405_A CF 3 BF 3 3) Damage due to service performed by an installer, service agency or Limited Warranty gas supplier, unless otherwise agreed to in writing by JØTUL. 4) Labor or other costs associated with the repair of gas controls, plumb- ing, burners, log set, or sheet metal firebox beyond the warranty period.
  • Page 3: Table Of Contents

    139405_A CF 3 BF 3 Table of Contents 1. Technical Information ......4 2. General Information ......5 3. Safety Information .........5 4. Installer Information ......6 5. User Information ........14 6. Troubleshooting ........16 7. Parts Illustrations and Lists ....19 8.
  • Page 4: Technical Information

    139405_A CF 3 BF 3 C ountries of Destination GB, IE Jøtul GF 3 BF 3 Appliance Category II 2H3P Technical Information Gas Types NG LPG (G20) (G31) State of Adjustment Material: Cast iron / steel Supply Pressure (mbar) 20 Finish: Matte Black Paint Blue Black Enamel Nominal Heat Input (Net, kW) 6.8...
  • Page 5: General Information

    Care should be taken compatible. not to touch unit when it is in operation. This product, the Jøtul GF 3 BF 3, may only be used WARNING! If you detect an odour of gas: ...
  • Page 6: Installer Information

    139405_A CF 3 BF 3 Installer Information 435 mm Installation Guide for Qualified 580 mm Personnel Figure 2. Minimum Hearth Protection. Important: The appliance is factory pre-set for Natural Gas G20. If Propane G31 is to be used, the appliance must be converted with the conversion kit (available on request and supplied with full installation instructions.
  • Page 7: Combustible Materials

    139405_A CF 3 BF 3 Flue System Installation achieved. This 5 metres when measured must include the Note! During the installation of the vent, it is important attached horizontal flue section of 600mm as the final to adhere to national and local regulations that apply. The item connected.
  • Page 8 139405_A CF 3 BF 3 Figure 6. Flueing Configurations. Fig. 6, a Fig. 6, b Fig. 6, c 400mm Max. Fig. 6, d Flue Arrangement 4 Vent restrictor position D This arrangement can only be made using kit M82671. The maximum permissible horizontal length is 400mm.
  • Page 9 139405_A CF 3 BF 3 Vent Restriction The GF3 BF3 is equipped with an Exhaust Restrictor Plate which enables you to regulate the flow of exhaust gas. The Exhaust Restrictor is an adjustable shutter located at the top right side of the firebox. It is adjusted by moving a pivot pin into one of two positions.
  • Page 10: Log Set Installation

    139405_A CF 3 BF 3 Assembly Prior To Installation Log Set Installation The product is delivered with 2 packages. The contents Brick Kit Note: Install the optional Antique Brick Kit 155370 include: before installing the log set. See instructions supplied with that kit.
  • Page 11 139405_A CF 3 BF 3 PN 220729 Figure 11. Install right log. PN 220728 Figure 12. Install left log. PN 220730 Figure 13. Install middle log. Figure 14. Spread ember stones over the burner plate.
  • Page 12: Gas Installation

    139405_A CF 3 BF 3 Commissioning Gas Installation Gas installation must only be performed by qualified Testing Gas Pressure personnel. It is important to adhere to national and local Correct gas pressure is important for the safe use of gas in regulations that apply.
  • Page 13: Annual Service

    139405_A CF 3 BF 3 Figure 16. Proper pilot flame Inspection of the Pilot Flame / carry-over port alignment. The pilot flame should have three flames as shown in fig. 16. The two thermo-elements should be surrounded by two of the flames as shown in fig. 17. The flames should be stable and the colour mainly blue.
  • Page 14: User Information

    139405_A CF 3 BF 3 User Information Operating Instructions Commissioning, Lighting NOTE! Odours may be present when using the stove for General the first time: General assembly, installation, maintenance and gas When used for the first time and hot, the appliance conversion (if required) must be performed by a qualified may emit a harmless, non-toxic odour.
  • Page 15: External Maintenance

    139405_A CF 3 BF 3 Figure 20. Valve Controls. Figure 21. Burner Control Switch. Adjusting the Heat Setting 3. Push in the gas control knob (B) a little and turn counter-clockwise to “PILOT”. Heat and flame size can be adjusted by turning the regu- 4.
  • Page 16: Troubleshooting

    139405_A CF 3 BF 3 Troubleshooting When No Spark is Generated at the Pilot Head It is uncommon for the Piezo spark ignitor (fig. 22-A) to fail, unless it has mechanical damage. If the spark is not conducted forward, it could be the result of a break in the electrical circuit leading up to the pilot head.
  • Page 17 139405_A CF 3 BF 3 When There is No Gas Flow Thermocouple (Fig. 23) and Thermopile To The Pilot Head (Fig. 24) A thermocouple is in principle a thermal generator This is the trouble-shooting procedure for the gas supply: and consists of a copper wire (copper-nickel alloy) and an Check if all gas connections are sealed by using strong iron wire twisted together.
  • Page 18 139405_A CF 3 BF 3 When There is No Gas Supply to the Burner. Figure 24. Thermopile system check. This is the trouble-shooting procedure for the electrical components: 1. Make sure the control knob on the valve is set to “ON”. Check the position on the “ON/OFF/Thermostat”...
  • Page 19: Parts Illustrations And Lists

    139405_A CF 3 BF 3 Jøtul GF 3 BF 3 Illustrated Parts Breakdown NOTE: THE GAS CONTROL VALVE ASSEMBLY IS MOUNTED AT THE CENTER FRONT OF ALL STOVES. NOTE: THE GAS CONTROL VALVE ASSEMBLY IS MOUNTED AT THE CENTER FRONT OF ALL STOVES.
  • Page 20 139405_A CF 3 BF 3 Jøtul GF 3 BF 3 Parts List Blue Black Ivory Brown Green Cast Iron Parts Matte Black Enamel Enamel Majolica Majolica Enamel Enamel Side Plate 10203292 102033 10203229 10203247 10203232 Base Plate 10390092 10390027 10390029...
  • Page 21 139405_A CF 3 BF 3 M82678 M82652 M82650 M82653 M82654 M82668 M87379 M87913 M30170 M82656 M82657 M82667 Figure 27. Approved Vent Components.
  • Page 22 139405_A CF 3 BF 3 M82655 M87196 M82661 M82671 Ø100/170mm L=400mm Figure 27a. Approved Vent Components.
  • Page 23: Service Record

    Annual service - year 9 Sign.: personnel. Company: Date: Service details: Model Name: Jøtul GF 3 BF 3 Serial No.: Annual service - year 10 Sign.: Purchase Date: Company: Date:...
  • Page 24 139405_A CF 3 BF 3 This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that the these instructions be carefully read and understood. Jøtul maintains a policy of continual product development. Consequently, products may differ in speci- fication, color or type of accessories from those illustrated or described in various publications.