Maintenance

This appliance and its venting system should be
inspected before use and at least annually by a
qualified service technician.
IMPORTANT:
ALWAYS TURN OFF THE GAS SUPPLY TO THE STOVE
BEFORE ANY SERVICE WORK IS PERFORMED ON THE
STOVE.
General cleaning: The firebox should be vacuumed
annually to remove any surface build up. Be sure to
vacuum or wipe off the pilot assembly and burner
orifice and burner plate. Also, when vacuuming the
log set, be sure to handle each piece carefully as they
are very fragile.
Gasket inspection: It is important that the glass
gasket be inspected at least annually. Examine the
rope gasket for signs of deterioration and make sure
the gasket has a positive seal. This is important to
prevent combustion gases from escaping into the
room. Replace the gasket if it is frayed, stiff or brit-
tle. Refer to the replacement parts list on page 26.
Always replace any damaged or broken parts on
the GF 600 DV II Firelight with JØTUL AUTHORIZED
PARTS ONLY. These are available through your Jøtul
dealer. Never use any substitute parts on your GF
600 DV II Firelight gas stove.
Glass Replacement
Use only Jøtul PN 129124 Tadpole Gasket and PN
12102633 Glass Panel for this appliance.
1. Release the spring clips at the top of the firebox
and slide the glass frame up and out of the fire-
box.
2. Use a flat blade screwdriver to bend the two side
retainer tabs up to release the original glass panel
and remove it from the frame.
3. Beginning at the center of one of the long sides,
wrap the new tadpole gasket material around
the new glass pane, pressing the adhesive firmly
against the glass surface. See fig. 39.
4. Place the glass panel within the frame oriented
with the gasket seam at the bottom and the thin-
ner side of the gasket against the frame. Care-
fully bend the retainer tabs back only enough to
secure the glass panel. See fig.40.
5. Replace the glass frame into the firebox.
24
Figure 39.
Replacing the Glass Gasket.
Retainer Tab
Figure 40.
Replacing the glass panel into the frame.