Fuel Conversion - Jøtul GF 600 DV II Firelight Installation And Operation Instructions Manual

Direct vent gas stove
Table of Contents

Advertisement

138090_Rev_F 7.29.10
The appliance and its main gas valve must be
disconnected from the gas supply piping system
during any pressure testing on that system at test
pressures in excess of 1/2 psig (3.5kPa).
The appliance must be isolated from the gas
supply line by closing its individual manual gas
shut-off valve (gas cock) during any pressure testing
of the gas supply piping system that is equal to or
exceeds pressures of 1/2 psig (3.5kPa).
MANIFOLD PRESSURES
NATURAL GAS
PROPANE
DO NOT ALLOW THE INLET GAS PRESSURE TO
EXCEED 13.5" WC (OR 1/2 PSIG) AS SERIOUS
DAMAGE TO THE VALVE MAY RESULT.

Fuel Conversion

The GF 600 DV II Firelight gas stove is shipped from
the factory equipped to burn NATURAL GAS. Use
the Fuel Conversion Kit included with the stove, to
convert the burner for use with Propane. The kit
contains all the necessary components needed to
complete the task and ensure safe operation, includ-
ing labels that must be affixed to the stove.
CAUTION: Before proceeding with this conver-
sion, the gas supply must be shut off prior to discon-
necting the electrical power.
THE CONVERSION KIT IS TO BE INSTALLED
BY AN AUTHORIZED JØTUL SERVICE
TECHNICIAN IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS AND
ALL CODES AND REQUIREMENTS OF
THE AUTHORITY HAVING JURISDICTION.
FAILURE TO FOLLOW THESE INSTRUCTIONS
COULD RESULT IN SERIOUS INJURY OR
PROPERTY DAMAGE. THE QUALIFIED
AGENCY PERFORMING THIS WORK ASSUMES
RESPONSIBILITY FOR THIS CONVERSION.
14
MIN
MAX
1.2 WC
3.8 WC
2.9 WC
11.0 WC
NOTICE:
WARNING:
Conversion Kit
(LPG #155893, NG #
155894)
Tools required:
• 1/4" nut driver
• 1/2" & 13 mm open end wrench or deep-well socket
• Torx T20 or slotted screwdriver
• 7/16" open end wrench
• 3 mm allen wrench
• 4 mm allen wrench
Conversion Kit Contents:
• 1 regulator tower labeled for propane
• 3 regulator tower screws
• 1 burner orifice (3.2 mm for NG, #49 for LP)
• 1 pilot orifice (#51 for NG, #30 for LP)
• Label A - to be completed and applied to the back
of the stove
• Label B - apply to the rating plate
• Small valve label - apply to valve body
• Conversion instructions
IN CANADA:
THE CONVERSION SHALL BE CARRIED OUT IN ACCOR-
DANCE WITH THE REQUIREMENTS OF THE PROVIN-
CIAL AUTHORITIES HAVING JURISDICTION AND IN
ACCORDANCE WITH THE REQUIREMENTS OF THE
CAN1-B149.1 & .2 INSTALLATION CODE.
Fuel Conversion Procedure
1. Turn off gas supply to the stove.
2. Remove the Grille and Top Plate.
3. Release the spring latches atop the firebox and
lift glass assembly up and out of the stove.
4. Remove the Logset and lift out the Rear Wall Skirt
and Burner Skirt, fig. 16.
Rear Wall Skirt
Burner Skirt
Figure 16. Lift the Rear Wall Skirt and Burner Skirts.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents